Enzymatic method for determination of CO2 in serum.

نویسندگان

  • R L Forrester
  • L J Wataji
  • D A Silverman
  • K J Pierre
چکیده

We describe an enzymatic method, requiring only 10 mul of serum, for determining CO2 as bicarbonate or dissolved gas. Phosphoenolpyruvate carboxylase catalyzes the reaction of HCO3- with phosphoenolypyruvate to give oxalacetate. The resulting NADH, in the presence of malate dehydrogenase, is oxidized to NAD+, and the decrease in absorbance at 340 nm is directly proportional to the amount of CO2 present in the sample. Reaction is complete in 3 to 6 min under assay conditions, and is linearly related to CO2 concentrations between 8 and 65 mmol/liter. Analytical recovery is 95-110% (average, 101%). Two laboratories compared values obtained by continuous-flow analysis. The resulting correlation coefficients were 0.966 and 0.987, values for the t-test were t(paired) equals 0.473 and t(paired) equals 0.334, and average day-to-day precisions (three concentrations) were 3.9% and 4.2%.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Enzymatic Colorimetric Method for the Quantitative Determination of Phenylalanine in Dry-Blood Spots

Phenylketonuria (PKU) is an autosomal recessive disorder, which is characterized by severe mental retardation, microcephaly and seizures. The symptoms of this disease can be prevented if detected soon after birth. Therefore, blood Phenylalanine (Phe) measurement is essential for the early diagnosis, treatment and dietary monitoring of PKU patients. The goal of this research was to introduce a r...

متن کامل

A New Potentiometric Sensor for Determination and Screening Phenylalanine in Blood Serum Based on Molecularly Imprinted Polymer

Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...

متن کامل

Study the effect of eight weeks incremental aerobic exercise training with zinc supplementation on Muscular Enzymatic activity of superoxide dismutase and serum leptine in adult male wistar rats

Background & Objective: The purpose of study, was to investigate the effect of 8weeks incremental aerobic training with zinc supplementation on muscular enzymatic activity of superoxide dismutase and serum leptine in wistar rats. Materials & Methods: 32 Wistar rats, randomly divided into 4groups (control, training, training +zinc and zinc). The training protocol consisted of running on treadmil...

متن کامل

A New Potentiometric Sensor for Determination and Screening Phenylalanine in Blood Serum Based on Molecularly Imprinted Polymer

Methods routinely utilized for detection of phenylalanine in new-born blood consist of enzymatic assays, lacking sensitivity and HPLC assays which are expensive and time-consuming to conduct. We, here, report for the first time, the construction of a phenylalanine sensitive electrode, on the basis of a selective molecularly imprinted polymer, offering sensitivity, economy and ease of use for th...

متن کامل

Serum Alpha-1-antitrypsin Evaluation by Three Electrophoretic, Enzymatic and Immunodiffussion Methods

Abstract Background & Objective: Alpha-1-antitrypsin (AAT) is the major component of the human plasma alpha-1 globulin proteins and acts as a major inhibitor of proteolytic enzymes, particularly elastase. AAT deficiency is accompanied by lung, liver and other disorders, therefore, AAT is clinically important and its precise evaluation is diagnostically critical. In present study serum AAT was e...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 22 2  شماره 

صفحات  -

تاریخ انتشار 1976