Estimation of bias with the single-zone assumption in measurement of residential air exchange using the perfluorocarbon tracer gas method.

نویسندگان

  • K Van Ryswyk
  • L Wallace
  • D Fugler
  • M MacNeill
  • M È Héroux
  • M D Gibson
  • J R Guernsey
  • W Kindzierski
  • A J Wheeler
چکیده

UNLABELLED Residential air exchange rates (AERs) are vital in understanding the temporal and spatial drivers of indoor air quality (IAQ). Several methods to quantify AERs have been used in IAQ research, often with the assumption that the home is a single, well-mixed air zone. Since 2005, Health Canada has conducted IAQ studies across Canada in which AERs were measured using the perfluorocarbon tracer (PFT) gas method. Emitters and detectors of a single PFT gas were placed on the main floor to estimate a single-zone AER (AER(1z)). In three of these studies, a second set of emitters and detectors were deployed in the basement or second floor in approximately 10% of homes for a two-zone AER estimate (AER(2z)). In total, 287 daily pairs of AER(2z) and AER(1z) estimates were made from 35 homes across three cities. In 87% of the cases, AER(2z) was higher than AER(1z). Overall, the AER(1z) estimates underestimated AER(2z) by approximately 16% (IQR: 5-32%). This underestimate occurred in all cities and seasons and varied in magnitude seasonally, between homes, and daily, indicating that when measuring residential air exchange using a single PFT gas, the assumption of a single well-mixed air zone very likely results in an under prediction of the AER. PRACTICAL IMPLICATIONS The results of this study suggest that the long-standing assumption that a home represents a single well-mixed air zone may result in a substantial negative bias in air exchange estimates. Indoor air quality professionals should take this finding into consideration when developing study designs or making decisions related to the recommendation and installation of residential ventilation systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimation of Uncertainty in Tracer Gas Measurement of Air Change Rates

Simple and economical measurement of air change rates can be achieved with a passive-type tracer gas doser and sampler. However, this is made more complex by the fact many buildings are not a single fully mixed zone. This means many measurements are required to obtain information on ventilation conditions. In this study, we evaluated the uncertainty of tracer gas measurement of air change rate ...

متن کامل

Modified Perfluorocarbon Tracer Method for Measuring Effective Multizone Air Exchange Rates

A modified procedure was developed for the measurement of the effective air exchange rate, which represents the relationship between the pollutants emitted from indoor sources and the residents' level of exposure, by placing the dosers of tracer gas at locations that resemble indoor emission sources. To measure the 24-h-average effective air exchange rates in future surveys based on this proced...

متن کامل

An Improvement in Cation Exchange Capacity Estimation and Water Saturation Calculation in Shaly Layers for One of Iranian Oil Fields

Water saturation and cation exchange capacity are the most significant parameters used to calculate a hydrocarbon zone potential. In clean formations, by applying the famous Archie model, which assumes that in the formation the only electric conductor is the formation water, the water saturation can be calculated. Additionally, in shaly sand formations this assumption may not be true as the ion...

متن کامل

بررسی ارتباط میان انتشار دی اکسید گوگرد و میست اسید سولفوریک با میزان مواجهه فردی کارکنان یکی از واحدهای مجتمع پتروشیمی

  Background and Aim   The oxides of sulphur are among those chemical substances that are increasingly used and their consumption is even growing in different places everyday. Sulphuroxides are used in chemical industries, paper manufacturing, printing rollers, recovering burned (consumed) coal, supplying and producing sulphuric acid, and in bleaching liquids. Determination and evaluation of th...

متن کامل

ارزیابی عملکرد هودهای آزمایشگاهی براساس استاندارد  ASHRAE 110  در

Background and Aim: Laboratory fume-hoods are the first-level protection for the laboratory staff against hazardous chemical pollutants. Considering the large numbers of personnel, especially in petrochemical industry laboratories, this project was carried out in order to assess the performance of laboratory hoods based on tracer gas (SF6).Materials and Methods: In this project 22 hoods in the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Indoor air

دوره 25 6  شماره 

صفحات  -

تاریخ انتشار 2015