A membrane-based displacement flow immunoassay.
نویسندگان
چکیده
The use of a membrane-based continuous flow displacement immunoassay for detection of nanomolar quantities of explosives is demonstrated, and the kinetics of this system are characterized through experimentation. Antibodies of 2,4,6-trinitrotoluene (TNT) are immobilized onto a porous membrane with surface reactive sites designed to facilitate the covalent binding of the antibody. After saturating the immobilized antibody binding sites with labeled antigen, target analyte is introduced in flow, and the displacement reactions are monitored using a fluorometer. The displaced labeled antigen detected is proportional to the concentration of the analyte introduced to the antibody-labeled antigen complex. Multiple assays were performed at flow rates of 2.0, 1.0, 0.50, and 0.25 mL/min using membranes saturated with varying TNT antibody concentrations. The signal intensity (i.e. the concentration of displaced labeled antigen) was independent of antibody concentration at 1.0 mL/min, but proportional to antibody concentration at 0.25 mL/min. Our data suggests that the lower flow rate created a longer interaction time between the injected analyte and the antibody-labeled antigen complex, resulting in greater displacement of the labeled antigen and higher signal intensities than seen at higher flow rates.
منابع مشابه
Trace detection of explosives using a membrane-based displacement immunoassay.
A compact membrane-based displacement immunoassay has been designed for rapid detection of explosive compounds 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) at high femtomole levels. The system consists of activated porous membranes, onto which either TNT or RDX antibodies are immobilized, that are inserted into microreactor columns, incorporated into a flow syst...
متن کاملEffect of antibody density on the displacement kinetics of a flow immunoassay.
This study investigates the effect of antibody density on the kinetics of a solid-phase displacement immunoassay. Conducted in flow under nonequilibrium conditions, the assay utilizes a monoclonal antibody to the cocaine metabolite benzoylecgonine, which has been immobilized onto Sepharose beads and saturated with fluorophore labeled antigen. Displacement of antibody-bound labeled antigen by no...
متن کاملDevelopment of a flow-based ultrafast immunoextraction and reverse displacement immunoassay: analysis of free drug fractions.
A flow-based method employing a reverse displacement immunoassay was combined with ultrafast immunoextraction and near-infrared fluorescence detection for the analysis of free drug fractions, using phenytoin as a model analyte. Factors considered in the design of this method included the sample application conditions, the design of the immobilized drug analog column, the utilization of antibodi...
متن کاملDevelopment of a Lateral Flow Immunoassay Using Recombinant Dense Granular Antigen (GRA) 7 to Detect Anti-Toxoplasma gondii IgG Antibodies
Toxoplasma gondii is an intracellular protozoan parasite that causes toxoplasmosis and is of medical importance in pregnant women and immunosuppressed patients. In recent years, many methods have been developed for the detection of infection caused by this parasite; however, most of the developed methods are not adequately sensitive. The dense granular antigen (GRA) ...
متن کاملLateral flow immunoassay: Present status, trends and future perspective in diseases detection
This article has no abstract.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Biosensors & bioelectronics
دوره 13 9 شماره
صفحات -
تاریخ انتشار 1998