Extraction Slits for First-Order STIS Spectra
نویسندگان
چکیده
ABSTRACT: Measurements of enclosed energy vs. extraction slit height and numerical simulations for first-order STIS spectra demonstrate the dependence of signal-to-noise (S/N) on the extraction slit height for different gratings, wavelengths, and signal levels. Slit heights of 11 pixels for G140L and G230L, and 7 pixels for the three CCD first-order modes are a reasonable compromise between photometric precision, achieved S/N, and spectral purity at most wavelengths. We recommend the implementation of these extraction slits for the pipeline and the default absolute flux calibration of archival STIS spectra of point sources.
منابع مشابه
Use of FP-SPLIT Slits for Reaching High Signal-to-Noise with MAMA Detectors
A pre-flight uncertainty for STIS was the extent to which the MAMA detectors would support high signal-to-noise observations given inherently low count rates, limitations on available flat fields, and the possibility of evolution in pixel-to-pixel response stability. This ISR reports on results from STIS/SMOV-7091 Pixel-to-pixel Response Stability in which spectra were acquired at high count le...
متن کاملAn Algorithm for Correcting CTE Loss in Spectrophotometry of Point Sources with the STIS CCD
The correction for the change in sensitivity with time for the STIS CCD modes is complicated by the gradual loss of charge transfer efficiency (CTE) of the CCD. The amount of this CTE loss depends on time in orbit, the location on the CCD chip with respect to the readout amplifier, the stellar signal strength, and the background level. Primary constraints on our correction algorithm are provide...
متن کاملCalstis6: Extraction of 1-D Spectra in the STIS Calibration Pipeline
This report updates and extends the discussion of STIS ISR 97-02 on the extraction of 1-D spectra performed by calstis6 in the STIS calibration pipeline. Calstis6 processes flatfielded, 2-D science images to produce one-dimensional spectra using an unweighted extraction algorithm. The resultant fluxand wavelength-calibrated spectra are stored in 3-D binary tables.
متن کاملA new CTE Correction Algorithm for Point Source Spectroscopy with the STIS CCD : Correcting for charge trap filling by the ‘ red halo ’ of the CCD Point Spread Function redward of 8000 Å
The CTE-related loss for spectrophotometry of point sources with the STIS CCD is parametrized in terms of dependencies on the signal level of the source spectrum within the extraction box, the background level, and the signal in the point spread function located between the standard extraction box and the read-out amplifier. Primary constraints on the CTE correction algorithm are provided by es...
متن کاملExtraction Heights for STIS Echelle Spectra
The optimum extraction height (h) for STIS echelle spectra of 7 pixels maximizes the signal-to-noise for all modes and encompasses more than 98% of the target flux. Reducing h from 11 to 7 pixels reduces the error in the background correction by 40% at Lyman-α. This 7 pixel extraction height perpendicular to the dispersion should be the default for echelle extractions in the pipeline.