Echocardiographic evaluation of intracardiac pacing catheters: M-mode and two-dimensional studies.

نویسندگان

  • W C Reeves
  • N C Nanda
  • S S Barold
چکیده

Thirty patients with right ventricular (RV) and 15 with coronary sinus (CS) pacing catheters were studied by M-mode echocardiography. RV catheters, detected in 23, appeared as linear echoes in the right ventricle during mitral valve recordings in 12, adjacent or superimposed on the tricuspid valve (TV) in 14, and immediately anterior to aortic root and pulmonary valve echoes in two with a redundant loop in RV outflow. In three with complete heart block, prominent systolic anterior movements of the TV occurred when atrial systole coincided with ventricular systole, probably due to catheter-induced TV "buckling" or exaggerated TV annular motion. Catheter echoes mimicked TV recordings in three, since its motion pattern was similar, although delayed and mimicked prolapsing right atrial myxomas in two because of multilayered complexes behind TV, while reverberations cluttering the left ventricle simulated structural echoes present in that cavity. CS catheters, detected in 14 as linear echoes in the area of atrial septum recorded behind the TV, showed typical small humps in late diastole/early systole. Cross-sectional echocardiography with a mechanical sector scanner demonstrated RV catheters at the RV apex in five of seven patients, while CS catheters were detected near the base of the atrial septum in three of five patients. Echocardiography has the potential to localize pacing catheters which are occasionally difficult radiologically or electrocardiographically. Failure to recognize catheter echo patterns may result in errors in echocardiographic interpretation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of position on echocardiographic diagnosis of mitral valve prolapse

Echocardiography has been accepted as the diagnostic modality of choice for mitral valve prolapse (MVP). The determine the effect of position on echocardiographic diagnosis of MVP, we examined 693 consecutive patients referred to the echocardiography laboratory because of suspected MVP. First, patients were examined using the usual standard M-Mode echocardiography( left parasternal third or fou...

متن کامل

Echocardiographic evaluation of young adults with nonhemorrhagic cerebral infarction.

We reviewed echocardiographic findings in patients aged 15 to 45 years with acute nonhemorrhagic cerebral infarction (NHCI). Among 132 patients with NHCI, 96 (72.7%) had M-mode and two-dimensional echocardiography, including contrast echocardiography with intravenous saline injection when clinically indicated. Echocardiograms were abnormal in 33 patients. Of these, 7 had other conditions that c...

متن کامل

Echocardiographic findings in athletic horses with pulmonary regurgitation

BACKGROUND: Determining the clinical significance of cardiac murmurs is widely considered in equine practice. Pulmonary murmurs are commonly detected in athletic horses. Echocardiography plays a leading role in assessment of these murmurs. OBJECTIVES: Echocardiographic evaluation of horses with pulmonary regurgitation and determining the importance of pulmonary valve murmurs. METHODS: A total n...

متن کامل

Echocardiographic assessment of myocardial infarction: comparison of a rat model in two strains

The purpose of this study was to induce myocardial infarction (MI) and compare the echocardiographic parameters and mortality ratio of Lewis inbred and Wistar outbred strain before and after the procedure to help choose the best one for MI studies. In this study MI was induced in 46 Lewis and 34 Wistar by occlusion of left anterior descending artery (LAD). Doppler, two-dimensional (2-D) and 2-D...

متن کامل

Normal pulsed wave Doppler echocardiographic parameters of Turkmen horses of Iran

Turkmen horse is one of the oldest and purest breeds in the world, but there is no information on Doppler echocardiographic parameters in this horse. In the present study, pulsed-wave (PW) Doppler echocardiography was performed on 42 clinically normal 3- to 15-year-old racing Turkmen horses. No cardiac disease was detected with two-dimensional (2-D) real-time, M-mode, and colour flow mapping. D...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 58 6  شماره 

صفحات  -

تاریخ انتشار 1978