Coracoclavicular ligament reconstruction: coracoid tunnel diameter correlates with failure risk.

نویسندگان

  • Lucas S Rylander
  • Todd Baldini
  • Justin J Mitchell
  • Michael Messina
  • Ian A Justl Ellis
  • Eric C McCarty
چکیده

The current study compared tunnel diameter as an independent risk factor for fixation failure from the coracoid after transcoracoid coracoclavicular reconstruction. The effect of variation in coracoid size and scapular bone density on fixation failure was also studied. Sixty-two cadaveric scapulae were randomized into 1 of 4 groups: a control group with no coracoid hole, a group with a 4-mm transcoracoid tunnel, a group with a 6-mm transcoracoid tunnel, and a group with a socket technique using a 6-mm hole superiorly with a 4-mm hole inferiorly. Bone density measures for all specimens were performed. Coracoid dimensions were quantified. Using a cortical button device, all specimens were loaded to failure with an Instron servohydraulic testing machine (Instron Corp, Canton, Massachusetts). All drilled specimens failed by button pullout, and all control specimens failed by coracoid fracture. Average pullout strength for each tunnel subgroup was as follows: 4 mm, 296.9 N; 6 mm, 146.2 N; 6-4 socket, 261.8 N; control, 762.9 N. No difference was found with respect to tunnel subgroups in base height (P=.25) or bone density (P=.44). Load to failure for the control group was significantly higher than for the other 3 techniques. The 4-mm tunnel load to failure was significantly higher than that for the 6-mm tunnel (P=.006). No difference was found between the 4-mm tunnel and the 6-4 socket technique (P=.853). Although it was not statistically significant, a very strong trend was seen toward increased strength of the 6-4 socket over the 6-mm tunnel (P=.051). The study results show that when employing a transcoracoid reconstruction technique, a 4-mm tunnel technique is significantly stronger than a 6-mm tunnel technique. None of the coracoids drilled with the various tunnels approached the strength of the native coracoid controls using a looped wire technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical Evaluation of Hole Diameter for Coracoclavicular Ligament Reconstruction on Coracoid Strength

INTRODUCTION: Many acromioclavicular joint injuries involve damage to the coracoclavicular (CC) ligaments. Some current techniques for CC ligament reconstruction utilize a hole drilled in the coracoid process for placement of a fixation device. Such a hole may increase the probability of coracoid fracture; however, there are no studies in literature that have attempted to evaluate the effects o...

متن کامل

Coracoid Process Avulsion Fracture at the Coracoclavicular Ligament Attachment Site in an Osteoporotic Patient with Acromioclavicular Joint Dislocation

Coracoid fractures are uncommon, mostly occur at the base or neck of the coracoid process (CP), and typically present with ipsilateral acromioclavicular joint (ACJ) dislocation. However, CP avulsion fractures at the coracoclavicular ligament (CCL) attachment with ACJ dislocation have not been previously reported. A 59-year-old woman receiving glucocorticoid treatment fell from bed and complaine...

متن کامل

Acromioclavicular joint injuries: diagnosis and management.

Acromioclavicular joint injuries represent nearly half of all athletic shoulder injuries, often resulting from a fall onto the tip of the shoulder with the arm in adduction. Stability of this joint depends on the integrity of the acromioclavicular ligaments and capsule as well as the coracoclavicular ligaments and the trapezius and deltoid muscles. Along with clinical examination for tenderness...

متن کامل

Bioabsorbable screw fixation in coracoclavicular ligament reconstruction.

The purpose of this study is to evaluate the biomechanical properties of stainless steel and bioabsorbable screw fixation of the clavicle to the base of the coracoid. Seven matched pairs of fresh frozen shoulders were prepared by removing all soft tissue except the acromioclavicular and coracoclavicular ligament complexes. The shoulders were randomly selected and fixed with 4.5-mm stainless ste...

متن کامل

Modes of Failure in Acromioclavicular Joint Reconstruction: a Biomechanical Analysis of Clavicular Motion and Its Role in Construct Failure

INTRODUCTION Shoulder separations are common injuries. Controversy exists over the optimal treatment. More importantly, no single reconstruction technique is widely accepted. Current operative management focuses on primary healing or reconstruction of the ligaments using local tissue or free tendon grafts with supplemental fixation. The objective of these techniques is to maintain reduction lon...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 37 6  شماره 

صفحات  -

تاریخ انتشار 2014