Fitting Helical Snake and Rotator Field Strength Measurements in Rhic

نویسنده

  • V. Ranjbar
چکیده

We examined recent multi-pole measurements for the helical snakes and rotators in RHIC to generate a full field map. Since multi-pole measurements yield real field values for BP field components we developed a unique technique to evaluate the full fields using a traditional finite element analysis software [1]. From these measurements we employed SNIG [2] to generate orbit and Spin plots. From orbit values we generated a transfer matrix for the first snake.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Siberian Snakes and Spin-Flipping in Storage Rings

A Siberian snake, which is a 180° spin rotator, can be used to preserve electrons', protons' or light ions' beam polarization during acceleration by forcing the spin tune to be constant and equal to 1/2, independent of the beam energy. A compact helical dipole snake, which creates only a small orbit excursion inside the snake, could be used in EPIC. Frequent polarization reversals, or spin-flip...

متن کامل

Strength and Range of Motion of Internal and External Rotator Muscles in Volleyball Players With and Without Uneven Shoulders

Objective: Performing repetitive overhead movements puts stress on the shoulder joint, leading to uneven shoulders and pain in the shoulder joint. The purpose of this study was to evaluate and compare the strength and Range of Motion (ROM) of internal and external rotator muscles in volleyball players with and without uneven shoulders. Methods: This is a descriptive and causal-comparative stud...

متن کامل

Engineering of the Ags Snake Coil Assembly*

Foundation module, the complex helical cuts are produced in a more efficient manner. Also, since Pro/E can easily construct variable pitch helixes (see Figure 1) the process of creating the helical paths was greatly simplified. The paths produced in this manner were parametric, meaning they could easily be changed without the need to reconstruct them as the design evolved. A 30% Snake supercond...

متن کامل

The strength of hip abductor and external rotator muscles and ACL rupture in male soccer players

The purpose of this study was to compare of hip abductor and external rotator muscles strength between male soccer players with ACl rupture and healthy male soccer players. 30 male participants (15 soccer players with ACL rupture as sample group and 15 healthy soccer players as control group) participated in this study. Hip abductor and external rotator muscles strength tests including nor...

متن کامل

Analytical Field Calculation of Helical Dipole Magnets for Rhic

The analytical expression for the magnetic field of helical coils is presented. In particular, the multipole coefficients are introduced for helical dipole magnets, which are essential components of Siberian Snakes and spin rotators for polarized proton acceleration at RHIC. In addition, the comparison between analytical and numerical calculations is presented for simple helical dipole magnets.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001