This review describes recent developments in microfabricated flow cytometers and related microfluidic devices that can detect, analyze, and sort cells or particles. The high-speed analytical capabilities of flow cytometry depend on the cooperative use of microfluidics, optics and electronics. Along with the improvement of other components, replacement of conventional glass capillary-based fluidics with microfluidic sample handling systems operating in microfabricated structures enables volume- and power-efficient, inexpensive and flexible analysis of particulate samples. In this review, we present various efforts that take advantage of novel microscale flow phenomena and microfabrication techniques to build microfluidic cell analysis systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low Cost Cytometer Based on a Dvd Pickup Head

Cytometry is a process that allows for measuring characteristics of single biological cells [1]. In this paper we report on a novel cytometric cell detector using a DVD pickup head. The system uses a microfluidic chip with a flow cell that allows for hydrodynamic focusing of the sample flow. The reflected optical signal intensity is influenced by particles that pass the beam and is measured dir...

متن کامل

Comparison of Two Flow Cytometric Methods for Detection of Human Invariant Natural Killer T Cells (iNKT)

Background: Invariant natural killer cells (iNKT) are an important immunoregulatory T cell subset. Currently several flow cytometry-based approaches exist for the identifi-cation of iNKT cells, which rely on using the 6B11 monoclonal antibody or a combina-tion of anti-Vα24 and anti-Vβ11 antibodies. Objective: The aim of this study was to compare the ability of two flow cytometry-based methods f...

متن کامل

Dynamics analysis of microparticles in inertial microfluidics for biomedical applications

Inertial microfluidics-based devices have recently attracted much interest and attention due to their simple structure, high throughput, fast processing and low cost. They have been utilised in a wide range of applications in microtechnology, especially for sorting and separating microparticles. This novel class of microfluidics-based devices works based on intrinsic forces, which cause micropa...

متن کامل

Use of Four-Color Flow Cytometric Assay for Discrimination of Hematogone from Lymphoblast: Critical Issue for MRD Assessment in B-ALL Patients

Background: Hematogones are normal B-cell precursor which can be seen in different physiological and pathological conditions. Due to variation in B-cell acute lymphoblastic leukemia (B-ALL) blasts immunophenotyping and interference of hematogones in minimal residual disease (MRD) assessment, precise discrimination of hematogones is very crucial.  The purpose of this study was to evaluate the ex...

متن کامل

Deficient Expression of Bruton's Tyrosine Kinase in Monocytes from X-Linked Agammaglobulinemia as Evaluated by a Flow Cytometric Analysis and its Clinical Application to Carrier Detection

Background: The B-cell defect in X-linked agammaglobulinemia (XLA) is caused by mutations in the gene for Bruton's tyrosine kinase (BTK). BTK mutations result in deficient expression of BTK protein in peripheral blood monocytes. Methods: Using the anti-BTK monoclonal antibody (48-2H), a flow cytometric analysis of intra cytoplasmic BTK protein expression in monocytes was performed to identify I...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Physiological measurement

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 2005