Enzyme-amplified immunoassays: a new ultrasensitive assay of thyrotropin evaluated.

نویسندگان

  • P M Clark
  • C P Price
چکیده

An enzyme-amplified immunoassay for thyrotropin has been evaluated. The lower limit of detection of the assay (mean + 3 SD of the zero standard) was 0.037 milli-int.unit/L and the precision was good, giving a working range of 0.13-24.0 milli-int.units/L. The accuracy of the assay was good, as judged from analytical-recovery experiments, analysis of external quality-assessment samples and comparison with in-house assays. No significant interferences or cross reactivities were identified. Assay of a 25-microL serum sample on the microtiter plate takes 3 h. Values for healthy subjects ranged from 0.4 to 4.0 milli-int.units/L. For 32 thyrotoxic patients thyrotropin concentrations were clearly suppressed and completely distinct from normal values. Patients taking triiodothyronine also showed lower concentrations. The enzyme-amplified immunoassay may thus be a suitable "front line" test for assessing thyroid function.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ultrasensitive thyrotropin immunoassay based on enzymatically amplified time-resolved fluorescence with a terbium chelate.

We describe an ultrasensitive, enzymatically amplified time-resolved fluorescence immunoassay of thyrotropin (thyroid-stimulating hormone) in serum with use of a terbium chelate as the detectable moiety. In this assay, thyrotropin is first simultaneously reacted with a solid-phase (microtiter well) monoclonal antibody and a soluble biotinylated monoclonal detection antibody. After washing, a st...

متن کامل

Time-resolved detection of lanthanide luminescence for ultrasensitive bioanalytical assays.

The principles and practice of the application of time-resolved lanthanide chelate luminescence (or fluorescence) as a detection method for ultrasensitive bioanalytical assays such as immunoassays and nucleic acid hybridization assays are reviewed. The various lanthanide chelate-based detection systems which have been developed for use in heterogeneous and homogeneous assay formats are describe...

متن کامل

Towards narrower analytical goals in routine laboratory work.

596 CLINICAL CHEMISTRY, Vol. 37, No. 4, 1991 1. Howanitz PJ, Howanitz JH, Lamberson HV, Ennis KM. Incidence and mechanism of spurious increases in serum thyrotropin. Clin Chem 1982;28:427-31. 2. Boscato LM, Stuart MC. Incidence and specificity of interference in two-site inununoassays. Clin Chem 1986;32:1491-5. 3. Boscato LM, Stuart MC. Heterophilic antibodies: a problem for all immunoassays. C...

متن کامل

Quantification of Human Chorionic Gonadotropin by Bovine Serum Albumin Nanoparticles

Background and Aims: Some nanoparticles can be used in immunoassays to increase sensitivity. This study aimed to evaluate a novel nano-immunoassay based on bovine serum albumin nanoparticles (BSA NPs). Materials and methods: At first, the nanostructure was synthesized, and then applied as a tag in the nano-immunoassay. Then the concentration of β-subunit of human chorionic gonadotropin ...

متن کامل

Enzyme-free strip biosensor for amplified detection of Pb2+ based on a catalytic DNA circuit.

A simple and enzyme-free strip biosensor for the amplified detection of Pb(2+) has been constructed based on a catalytic DNA circuit. This assay is ultrasensitive, enabling the visual detection of Pb(2+) concentrations as low as 10 pM without instrumentation.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 32 1 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1986