Communication: Demonstration of a 20 ps X-ray switch based on a photoacoustic transducer

نویسندگان

  • A. Jarnac
  • Xiaocui Wang
  • Å. U. J. Bengtsson
  • J. C. Ekström
  • H. Enquist
  • A. Jurgilaitis
  • D. Kroon
  • A. I. H. Persson
  • V.-T. Pham
  • C. M. Tu
  • J. Larsson
چکیده

We have studied an X-ray switch based on a gold coated indium antimonide crystal using time-resolved X-ray diffraction and demonstrated that the switch could reduce the pulse duration of a 100 ps X-ray pulse down to 20 ps with a peak reflectivity of 8%. We have used a dynamical diffraction code to predict the performance of the switch, which was then confirmed experimentally. The experiment was carried out at the FemtoMAX beamline at the short-pulse facility of the MAX IV laboratory. The performance and limitation of the switch are discussed in terms of acoustic transport properties between the two materials and the electron transport properties of gold.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Iterative algorithm for multiple illumination photoacoustic tomography (MIPAT) using ultrasound channel data

Photoacoustic tomography is a promising imaging modality offering high ultrasonic resolution with intrinsic optical contrast. However, quantification in photoacoustic imaging is challenging. We present an algorithm for quantitative photoacoustic estimation of optical absorption and diffusion coefficients based on minimizing an error function between measured photoacoustic channel data and a cal...

متن کامل

B-Mode Photoacoustic Imaging using Linear Array: Numerical Study for Forward-Backward Minimum Variance Beamformer Combined with Delay-Multiply-and-Sum

Photoacoustic imaging (PAI) is a promising medical imaging modality which provides the resolution of Ultrasound (US) and the contrast of Optical imaging modalities. One of the most important challenges in PAI is image formation, especially in the case that a linear-array US transducer is used for data acquisition. This is due to the fact that in the linear-array scenario, there is only 60 degre...

متن کامل

Parallel acoustic delay lines for photoacoustic tomography.

Achieving real-time photoacoustic (PA) tomography typically requires multi-element ultrasound transducer arrays and their associated multiple data acquisition (DAQ) electronics to receive PA waves simultaneously. We report the first demonstration of a photoacoustic tomography (PAT) system using optical fiber-based parallel acoustic delay lines (PADLs). By employing PADLs to introduce specific t...

متن کامل

Influence of nanoscale temperature rises on photoacoustic generation: Discrimination between optical absorbers based on thermal nonlinearity at high frequency

In this work, we experimentally investigate thermal-based nonlinear photoacoustic generation as a mean to discriminate between different types of absorbing particles. The photoacoustic generation from solutions of dye molecules and gold nanospheres (same optical densities) was detected using a high frequency ultrasound transducer (20 MHz). Photoacoustic emission was observed with gold nanospher...

متن کامل

X-ray acoustic computed tomography with pulsed x-ray beam from a medical linear accelerator.

PURPOSE The feasibility of medical imaging using a medical linear accelerator to generate acoustic waves is investigated. This modality, x-ray acoustic computed tomography (XACT), has the potential to enable deeper tissue penetration in tissue than photoacoustic tomography via laser excitation. METHODS Short pulsed (μs-range) 10 MV x-ray beams with dose-rate of approximately 30 Gy∕min were ge...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2017