A Simulation for Estimation of the Blood Pressure using Arterial Pressure-volume Model

نویسنده

  • Chul - han Kim
چکیده

A analysis on the conventional the blood pressure estimation method using an oscillometric sphygmomanometer was performed through a computer simulation using an arterial pressure-volume (APV) model. Traditionally, the maximum amplitude algorithm (MAP) was applied on the oscillation waveforms of the APV model to obtain the mean arterial pressure and the characteristic ratio. The estimation of mean arterial pressure and characteristic ratio was significantly affected with the shape of the blood pressure waveforms and the cutoff frequency of high-pass filter (HPL) circuitry. Experimental errors are due to these effects when estimating blood pressure. To find out an algorithm independent from the influence of waveform shapes and parameters of HPL, the volume oscillation of the APV model and the phase shift of the oscillation with fast fourier transform (FFT) were testified while increasing the cuff pressure from 1 mmHg to 200 mmHg (1 mmHg per second). The phase shift between the ranges of volume oscillation was then only observed between the systolic and the diastolic blood pressures. The same results were also obtained from the simulations performed on two different the arterial blood pressure waveforms and one hyperthermia waveform. Keywords—Arterial blood pressure, oscillometric method. This work was supported by health medical technology research of Ministry of Health and Welfare. (02-PJ3-PG6-EV05-0001) Gye-rok Jeon is with the Department of Biomedical Engineering College of Medicine, Pusan National University, Busan, Korea (e-mail: [email protected]). Jae-hee Jung is with the Department of Interdisciplinary program in Biomedical Engineering, Pusan National University, Busan, Korea (e-mail: espouir82 @hanmail.net). In-cheol Kim is with the Department of Interdisciplinary program in Biomedical Engineering, Pusan National University, Busan, Korea (e-mail: [email protected]). A-young Jeon is with the Department of Interdisciplinary program in Biomedical Engineering, Pusan National University, Busan, Korea (e-mail: [email protected]). Sang-hwa Yoon is with PhysioLab Corp., Busan, Korea (e-mail: [email protected]). Jung-man Son is with T.P. Technology Inc., Gyeonggi, Korea (e-mail: [email protected]). Jae-hyung Kim is with the Department of Physics, Inje University, Kyungnam, Korea (e-mail: [email protected]). Soo-young Ye is the BK21 Medical Science Education Center, School of medicine,Pusan National Universiry, Busan, Korea (e-mail: [email protected]). Jung-hoon Ro is with the Department of Biomedical Engineering College of Medicine,Pusan National University, Busan, Korea (e-mail: [email protected]) Dong-hyun Kim is with center for health promotion of Pusan National University hospital, Busan, Korea ([email protected]). Chul-han Kim is with the Department of Electrical Engineering, Dong-A University, Busan, Korea (Corresponding author to provide phone: 82-51-257-2866; fax: 82-51-257-2867; e-mail: [email protected]).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis

Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...

متن کامل

Blood Flow Simulation in an Aorta with a mild coarctation Using Magnetic Resonance Angiography and Finite Volume Method

Coarctation of the aorta is one of the five main congenital cardiovascular failures, accounting for 6–8 percent of these failures. This research aimed to simulate the blood flow of a seventeen-year-old male teen with a mild coarctation at one-third of his aorta's descending branch. The simulation was performed by extracting the domain and the input pulsatile velocity signal as the boundary cond...

متن کامل

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

The effect of nucleus tractus solitarius inactivation on blood pressure in diabetic rats

The role of nucleus tractus solitarius (NTS) in cardiovascular system regulation is controversial. On the other hand, the problem of hypertension in diabetic animals is the subject of many research programs. The aim of present study was to determine whether inactivation of NTS could affect blood pressure and heart rate in diabetic rats. To this end, stereptozotocin induced diabetic rats were an...

متن کامل

The effect of nucleus tractus solitarius inactivation on blood pressure in diabetic rats

The role of nucleus tractus solitarius (NTS) in cardiovascular system regulation is controversial. On the other hand, the problem of hypertension in diabetic animals is the subject of many research programs. The aim of present study was to determine whether inactivation of NTS could affect blood pressure and heart rate in diabetic rats. To this end, stereptozotocin induced diabetic rats were an...

متن کامل

Presentation of a Non-invasive Method of Estimating Arterial Stiffness by Modeling Blood Flow and Arterial Wall Based on the Determination of Elastic Module of Arterial Wall

Introduction: Arterial stiffness is an important predictor of cardiovascular risk. Several indices have been  introduced to estimate the arterial stiffness based on the changes in the brachial blood pressure. Since the  substitution  of  the  blood  pressure  changes  in  the  central  arteries  such  as  carotid  with  the  blood  pressure  changes in the brachial results in error in the blood...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012