Towards Standardization of Quantitative Retinal Vascular Parameters: Comparison of SIVA and VAMPIRE Measurements in the Lothian Birth Cohort 1936

نویسندگان

  • Sarah McGrory
  • Adele M. Taylor
  • Enrico Pellegrini
  • Lucia Ballerini
  • Mirna Kirin
  • Fergus N. Doubal
  • Joanna M. Wardlaw
  • Alex S. F. Doney
  • Baljean Dhillon
  • John M. Starr
  • Emanuele Trucco
  • Ian J. Deary
  • Thomas J. MacGillivray
چکیده

Purpose Semiautomated software applications derive quantitative retinal vascular parameters from fundus camera images. However, the extent of agreement between measurements from different applications is unclear. We evaluate the agreement between retinal measures from two software applications, the Singapore "I" Vessel Assessment (SIVA) and the Vessel Assessment and Measurement Platform for Images of the Retina (VAMPIRE), and examine respective associations between retinal and systemic outcomes. Method Fundus camera images from 665 Lothian Birth Cohort 1936 participants were analyzed with SIVA and VAMPIRE. Intraclass correlation coefficients (ICC) and Bland-Altman plots assessed agreement between retinal parameters: measurements of vessel width, fractal dimension, and tortuosity. Retinal-systemic variable associations were assessed with Pearson's correlation, and intersoftware correlation magnitude differences were examined with Williams's test. Results ICC values indicated poor to limited agreement for all retinal parameters (0.159-0.410). Bland-Altman plots revealed proportional bias in the majority, and systematic bias in all measurements. SIVA and VAMPIRE measurements were associated most consistently with systemic variables relating to blood pressure (SIVA r's from -0.122 to -0.183; VAMPIRE r's from -0.078 to -0.177). Williams's tests indicated significant differences in the magnitude of association between retinal and systemic variables for 7 of 77 comparisons (P < 0.05). Conclusions Agreement between two common software applications was poor. Further studies are required to determine whether associations with systemic variables are software-dependent. Translational Relevance Standardization of the measurement of retinal vascular parameters is warranted to ensure that they are reliable and application-independent. This would be an important step towards realizing the potential of the retina as a source of imaging-derived biomarkers that are clinically useful.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retinal microvascular network geometry and cognitive abilities in community-dwelling older people: The Lothian Birth Cohort 1936 study

AIM To examine the relationship between retinal vascular morphology and cognitive abilities in a narrow-age cohort of community-dwelling older people. METHODS Digital retinal images taken at age ∼73 years from 683 participants of the Lothian Birth Cohort 1936 (LBC1936) were analysed with Singapore I Vessel Assessment (SIVA) software. Multiple regression models were applied to determine cross-...

متن کامل

Retinal Vascular Fractal Dimension, Childhood IQ, and Cognitive Ability in Old Age: The Lothian Birth Cohort Study 1936

PURPOSE Cerebral microvascular disease is associated with dementia. Differences in the topography of the retinal vascular network may be a marker for cerebrovascular disease. The association between cerebral microvascular state and non-pathological cognitive ageing is less clear, particularly because studies are rarely able to adjust for pre-morbid cognitive ability level. We measured retinal v...

متن کامل

Intellect and cognitive performance in the Lothian Birth Cohort 1936.

Investment personality traits are thought to positively affect cognitive performance in old age, even after controlling for prior cognitive ability. In the Lothian Birth Cohort 1936 (N = 1,091), a cross-lagged model tested for reciprocal effects of the investment trait Intellect on verbal fluency, an indicator of crystallized intelligence, at age 70 and 73 years, while adjusting for general IQ ...

متن کامل

Stability and change in intelligence from age 11 to ages 70, 79, and 87: the Lothian Birth Cohorts of 1921 and 1936.

Investigating the predictors of age-related cognitive change is a research priority. However, it is first necessary to discover the long-term stability of measures of cognitive ability because prior cognitive ability level might contribute to the amount of cognitive change experienced within old age. These two issues were examined in the Lothian Birth Cohorts of 1921 and 1936. Cognitive ability...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2018