Screw Back-Out Following "Open-Door" Cervical Laminoplasty: A Review of 165 Plates

نویسندگان

  • Gabriel Liu
  • Jacob M. Buchowski
  • K. Daniel Riew
چکیده

STUDY DESIGN Retrospective study. PURPOSE To investigate safety profile of open door laminoplasty plates. OVERVIEW OF LITERATURE Few reports have documented potential complications related to the use of cervical laminoplasty plates. METHODS Records and radiographs of consecutive plated laminoplasty patients of one academic surgeon were analyzed. Group 1 had screw back-out, defined as change in screw position, and group 2 did not. RESULTS Forty-two patients (mean age, 56.9) underwent "open-door" cervical laminoplasty using 165 plates. Mean follow-up was 24 months (range, 12-49 months). Mean Nurick grade improved from 2.1 to 0.9 postoperatively. Cervical lordosis (C2-7) was 12.1° preoperatively and 10.0° postoperatively. Range-of-motion was 27.0° preoperatively and 23.4° postoperatively. Partial screw back-out was noted in 27 of 165 plates (16.4%) and in 34 of 660 screws (5.2%). Of the 34 screws, 27 (79.4%) were at either the most cranial (12/27, 44.4%) or the most caudal (15/27, 55.5%) level. Cranially, 11/12 screws (91.7%) had back-out. Caudally, 9/15 lateral mass screws (60.0%) backed-out versus 6 laminar screws (40.0%). Of the 22 patients with screw back-out, 15 (68.2%) occurred <3 months postoperative and 6 (27.3%) occurred 4-12 months postoperative. No statistical differences were found between group 1 and 2 for age, gender, preoperative and postoperative lordosis, focal sagittal alignment, range-of-motion, or Nurick grade. Despite screw backout in 22 patients, there were no plate dislodgements, laminoplasty closure, or neurological deterioration. CONCLUSIONS Although screw back-out may occur with the use of cervical laminoplasty plates, the use of these plates without a bone block appears to be safe and reliable. As screw back-out is most common at the cranial and caudal ends of the laminoplasty, we recommend using the maximum number of screws (typically 2 for the lateral mass and 2 for the spinous process) at these levels to secure the plate to the bone.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative Effectiveness of Different Types of Cervical Laminoplasty

Study Design Systematic review. Study Rationale Numerous cervical laminoplasty techniques have been described but there are few studies that have compared these to determine the superiority of one over another. Clinical Questions The clinical questions include key question (KQ)1: In adults with cervical myelopathy from ossification of the posterior longitudinal ligament (OPLL) or spondylosis, w...

متن کامل

Clinical application of a new plate fixation system in open-door laminoplasty.

The purpose of this retrospective clinical series was to evaluate the benefits and complications of plate fixation for open-door laminoplasty in cervical spondylotic myelopathy with multilevel spinal stenosis compared with open-door laminoplasty without fixation. Forty-nine patients underwent open-door laminoplasty for cervical myelopathy with multilevel spinal stenosis with at least 13 months ...

متن کامل

Risk Factors for Delayed Hinge Fracture after Plate-Augmented Cervical Open-Door Laminoplasty

OBJECTIVE Delayed hinge fracture (HF) that develops after cervical open door laminoplasty can be a source of postoperative complications such as axial pain. However, risk factors related to this complication remain unclear. We performed a retrospective clinical series to determine risk factors for delayed HF following plate-only open-door cervical laminoplasty. METHODS Patients who underwent ...

متن کامل

Posterior Cervical Pedicle Screw-Rod/Plate Instrumentation Combined with Unilateral Open-Door Laminoplasty for the Treatment of Acute Cervical Spinal Cord Compression Injury: Report of Five Cases.

All patients were acute, multi-segment cervical spinal cord compression injury secondary to subaxial cervical spine fracture. These patients underwent emergency posterior cervical pedicle screw-rod/plate instrumentation combined with unilateral open-door laminoplasty. Well-placed pedicle screws and good cervical canal dilation were achieved in all patients, as assessed by radiography. Patients ...

متن کامل

[Pullout test in expansive unilateral open-door laminoplasty of the cervical spine with OsteoMed M3 plate and screws: the screw orientation matters].

OBJECTIVE To study the impact of screw orientation on the pullout strength of OsteoMed M3 titanium screws in expansive unilateral open-door laminoplasty of the cervical spine. METHODS Six fresh human cervical spine specimens were randomly numbered and OsteoMed M3 plate and screws were used for an expansive unilateral open-door laminoplasty. The screws were inserted in the lateral mass at diff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015