Astigmatism and Refractive Outcome After Late In-The-Bag Intraocular Lens Dislocation Surgery: A Randomized Clinical Trial.
نویسندگان
چکیده
Purpose To compare surgically induced astigmatism (SIA) and refractive outcomes between two operation methods for late in-the-bag IOL dislocation. Methods In this prospective, randomized, parallel-group clinical trial, 104 patients (eyes) were assigned to IOL repositioning by scleral suturing 1.5- to 2-mm posterior to limbus (n = 54) or IOL exchange with a retropupillar iris-claw IOL using a 5.5-mm scleral pocket incision (n = 50). The SIA was determined by vector analysis through conversion of corneal cylinders to Cartesian coordinates, and is presented as magnitude in diopters @ direction in degrees (D @ °). Follow-up was 6 months. Results The SIA was 0.24 D @ 8° for IOL repositioning and 0.65 D @ 171° for IOL exchange, which was a nonsignificant group difference (X coordinate: P = 0.08; Y coordinate: P = 0.16). Mean SIA magnitude was 0.60 ± 0.50 D and 1.12 ± 0.85 D, respectively (P < 0.001). Mean postoperative spherical equivalent was -1.6 ± 1.6 D after IOL repositioning and -0.5 ± 1.0 D after IOL exchange (P < 0.001). For IOL repositioning, this represented a mean myopic shift of -0.7 ± 1.1 D compared with before the IOL dislocation (P < 0.001). For IOL exchange, it was within ±1 D of target refraction in 83% of the patients. Conclusions Surgically induced astigmatism was modest in both operation groups, albeit with a tendency of being more pronounced for IOL exchange. Repositioning surgery led to a myopic shift, whereas exchange surgery provided good refractive predictability.
منابع مشابه
Refractive Error and Anterior Segment Parametric Changes in Patients with Posterior Capsular Opacification after Nd: YAG Laser Posterior Capsulotomy
Background and Objective: Cataract is one of the most common causes of blindness in the world, and posterior capsular opacification (PCO) is the most common complication after cataract surgery. Nd: YAG laser posterior capsulotomy is a standard method for the treatment of PCO. The aim of this study was to investigate the effects of Yas laser capsulotomy on anterior segment parameters and lenticu...
متن کاملPrediction of Refractive Outcome of Second Eye with Partial Adjustment of Intraocular Lens Power of the First Eye
Background and Objective: This study aimed at comparing the results of refractive cataract surgery in patients undergoing sequential surgeries in both eyes. Considering the preoperative refraction and final refraction of the first eye, it is possible to correct the refrative result of cataract surgery using the adjustment of the second eye intraocular lens (IOL) power. Materials and Methods: T...
متن کاملToric vs aspherical control intraocular lenses in patients with cataract and corneal astigmatism: a randomized clinical trial.
IMPORTANCE Spectacle independence is becoming increasingly important in cataract surgery. Not correcting corneal astigmatism at the time of cataract surgery will fail to achieve spectacle independency in 20% to 30% of patients. OBJECTIVE To compare bilateral aspherical toric with bilateral aspherical control intraocular lens (IOL) implantation in patients with cataract and corneal astigmatism...
متن کاملIn-bag dislocation of intraocular lens in patients with uveitis: a case series
BACKGROUND Improvement in surgical devices and intraocular lenses has made modern cataract surgery a safe procedure with decreasing complication rates. Intraocular lens dislocation is a serious complication after cataract surgery. Although most dislocations occur during the first week postoperative period, late intraocular lens dislocation occurring 3 months or later post-surgery has been repor...
متن کاملClinical Outcomes and Capsular Bag Stability of a Four-Point Haptic Bitoric Intraocular Lens.
PURPOSE To evaluate the visual, refractive, and aberrometric outcomes of a bitoric intraocular lens (IOL) and its stability and alignment within the capsular bag. METHODS A retrospective study including 41 eyes of 24 patients with preexisting corneal astigmatism of 0.75 diopters or greater undergoing cataract surgery with implantation of the bitoric IOL AT TORBI 709M (Carl Zeiss Meditec, Jena...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 58 11 شماره
صفحات -
تاریخ انتشار 2017