Combination of physical exercise and adenosine improves accuracy of automatic calculation of stress LVEF in gated SPECT using QGS software.

نویسندگان

  • Neda Tehranipour
  • Adil Al-Nahhas
  • David J Towey
چکیده

BACKGROUND Combining exercise and adenosine during the stress phase of myocardial perfusion imaging (MPI) is known to reduce adverse effects and improve image quality. The aim of this study was to assess whether it can also improve the automatic calculation of left ventricular ejection fraction (LVEF) by QGS software package, during the stress phase of Gated SPECT. MATERIAL AND METHODS One hundred patients who had stress Gated SPECT were retrospectively included in this study. Gated data of those who had adenosine only (50 patients=group A) was compared with those obtained in another group of 50 patients who had added bicycle exercise (Group B). All had identical image acquisition protocol using (99m)Tc-tetrofosmine. Clinical adverse effects, changes in blood pressure (BP), heart rate (HR), and ECG were monitored. Visual assessment of subdiaphragmatic uptake and accuracy of automatic regions of interest (ROI's) drawn by the software were noted. Regions of interest that involved sub-diaphragmatic uptake and resulting in low LVEF were manually adjusted to include the left ventricle only, and the frequency of manual adjustment was noted. RESULTS No significant difference was noted in age, sex, baseline BP and HR between groups A and B. Adverse effects occurred less often in group B compared to group A (12% vs. 24%, p=0.118). Maximum HR and BP achieved during stress were significantly higher in group B compared to group A (p=0.025, p=0.001 respectively). The number of patients who had faulty ROI's and low LVEF, who needed manual adjustment of ROI's, were higher in group A compared to group B (16% vs. 6%, p=0.025). The values of LVEF showed significant improvement following manual adjustment of ROI's, increasing from a mean of 19.63+/-15.96 to 62.13+/-7.55 (p=0.0001) and from 17.33+/-9.5 to 49.67+/- 7.7 (p=0.0014) in groups A and B respectively. CONCLUSION The addition of exercise to adenosine significantly improves the automatic calculation of LVEF by QGS software during Gated SPECT and reduces the need for manual adjustment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dipyridamole stress and rest gated 99mTc-sestamibi myocardial perfusion SPECT: left ventricular function indices and myocardial perfusion findings

  Introduction: We investigated the difference in left ventricular ejection fraction (LVEF) and end-systolic volume(ESV) measured by gated myocardial perfusion SPECT (GSPECT) in the post-dipyridamole stress and rest periods, and compared the results with the perfusion patterns found in the conventional non-gated tomograms. Methods: 297 consecutive patients were studie...

متن کامل

Normal values of left ventricular functional indices in gated 99mTc-MIBI myocardial perfusion SPECT

  Introduction: Although left ventricular(LV) function parameters measured by gated myocardial perfusion SPECT (GSPECT) have been validated, experimental data have revealed that the calculated the LV function parameters using GSPECT are affected by patient populations as well as particular acquisition and processing conditions. We tried to determine the normal values ...

متن کامل

Determination of normal ranges of regional and global phase parameters using gated myocardial perfusion imaging with Cedars-Sinai’s QGS software

Introduction: Myocardial perfusion imaging using gated SPECT and phase analysis is an effective tool in evaluation of mechanical dyssynchrony. The purpose of this study was to determine the normal ranges of global and regional phase parameters. Methods: A total of 100 patients with normal resting and stress electrocardiograms, low pretest likelihood for c...

متن کامل

Improved accuracy in estimation of left ventricular function parameters from QGS software with Tc-99m tetrofosmin gated-SPECT: a multivariate analysis.

UNLABELLED The purpose of this study was to verify whether the accuracy of left ventricular parameters related to left ventricular function from gated-SPECT improved or not, using multivariate analysis. METHODS Ninety-six patients with cardiovascular diseases were studied. Gated-SPECT with the QGS software and left ventriculography (LVG) were performed to obtain left ventricular ejection frac...

متن کامل

Left Ventricular Ejection Fraction Measured from Tc-Sestamibi Myocardial Perfusion Gated SPECT: Comparison with Echocardiography

Received 9/25/2009; revised 10/21/2009; accepted 10/23/2009. For correspondence and reprints contact: Hsiu-Lan Chu, Department of Nuclear Medicine, Kaohsiung Medical University Hospital. 100 Tzyou 1st Road, San-Ming District, Kaohsiung 807, Taiwan. Tel: (886)7-3121101 ext. 7152, Fax: (886)73117521, E-mail: [email protected] Purpose: The aim of this study was to compare the estimated LVEF be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Nuclear medicine review. Central & Eastern Europe

دوره 8 2  شماره 

صفحات  -

تاریخ انتشار 2005