Air filter materials, outdoor ozone and building-related symptoms in the BASE study.
نویسندگان
چکیده
UNLABELLED Used ventilation air filters have been shown to reduce indoor environmental quality and worker performance and increase symptoms, with effects stronger after reaction of filters with ozone. We analyzed data from the US EPA Building Assessment Survey and Evaluation (BASE) study to determine if ozone and specific filter media have interactive effects on building-related symptoms (BRS). We analyzed a subset of 34 buildings from the BASE study of 100 US office buildings to determine the separate and joint associations of filter medium [polyester/synthetic (PS) or fiberglass (FG)] and outdoor ozone concentration (above/below the median, 67.6 microg/m(3)) with BRS. Using logistic regression models and general estimating equations, we estimated odds ratios (ORs) and 95% confidence intervals for the association of filter medium, ozone, and filter medium x ozone with BRS. Relative to FG + low ozone, PS alone or high ozone alone, were each significantly (P < 0.05) associated only with fatigue/difficulty concentrating (ORs = 1.93 and 1.54, respectively). However, joint exposure to both PS + high ozone, relative to FG + low ozone, had significant associations with lower and upper respiratory, cough, eye, fatigue, and headache BRS (ORs ranged from 2.26 to 5.90). Joint ORs for PS + high ozone for lower and upper respiratory and headache BRS were much greater than multiplicative, with interaction P-values <0.10. Attributable risk proportion (ARP) estimates indicate that removing both risk factors might, given certain assumptions, reduce BRS by 26-62%. These findings suggest possible adverse health consequences from chemical interactions between outdoor ozone and PS filters in buildings. Results need confirmation before recommending changes in building operation. However, if additional research confirms causal relationships, ARP estimates indicate that appropriate filter selection may substantially reduce BRS in buildings, especially in high-ozone areas. PRACTICAL IMPLICATIONS The results indicate that a better understanding of how filters interact with their environment is needed. While the mechanism is unknown and these findings need to be replicated, they indicate that the joint risk of BRS from polyester/synthetic filters and outdoor ozone above 67.6 microg/m(3) is much greater than the risk from each alone. These findings suggest potential reductions in BRS from appropriate selection of ventilation filter media or implementing strategies to reduce ozone entrained in building ventilation systems. If the relationships were found to be causal, filter replacement and ozone abatement should be undertaken.
منابع مشابه
Asthmatic Symptoms among Pupils in Relation to Winter Indoor and Outdoor Air Pollution in Schools in Taiyuan, China
BACKGROUND There are few studies on associations between children's respiratory heath and air pollution in schools in China. The industrial development and increased traffic may affect the indoor exposure to air pollutants in school environment. Moreover, there is a need to study respiratory effects of environmental tobacco smoke (ETS) and emissions from new building materials in homes in China...
متن کاملبررسی غلظت مونواکسیدکربن هوای داخل ساختمان و هوای آزاد شهر بیرجند (شهریور تا اسفند 1393)
Background and Aim: One of the notorious air pllutants on which air quality is determined is carbon monoxide (CO). The aim of the present study was to measure the concentration of CO outdoor and indoor urban environments and compare it with air quality standards within buildings and open spaces. Materials and Methods: This research was a descriptive-analytical study of CO estimation in ou...
متن کاملMucous membrane and lower respiratory building related symptoms in relation to indoor carbon dioxide concentrations in the 100-building BASE dataset.
UNLABELLED Indoor air pollutants are a potential cause of building related symptoms and can be reduced by increasing ventilation rates. Indoor carbon dioxide (CO(2)) concentration is an approximate surrogate for concentrations of occupant-generated pollutants and for ventilation rate per occupant. Using the US EPA 100 office-building BASE Study dataset, we conducted multivariate logistic regres...
متن کاملA method to measure the ozone penetration factor in residences under infiltration conditions: application in a multifamily apartment unit.
Recent experiments have demonstrated that outdoor ozone reacts with materials inside residential building enclosures, potentially reducing indoor exposures to ozone or altering ozone reaction byproducts. However, test methods to measure ozone penetration factors in residences (P) remain limited. We developed a method to measure ozone penetration factors in residences under infiltration conditio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Indoor air
دوره 18 2 شماره
صفحات -
تاریخ انتشار 2008