Phase versus amplitude sorting of 4D‐CT data

نویسندگان

  • Nicole M. Wink
  • Christoph Panknin
  • Timothy D. Solberg
چکیده

Image quality of CT scans suffers when objects undergo motion. Respiratory motion causes artifacts, which prevents adequate visualization of anatomy. Four-dimensional CT (4D-CT) is a method in which image reconstruction of moving objects is retrospectively gated according to the recorded phase information of the monitored motion pattern. Although several groups have investigated the use of 4D-CT in radiotherapy, little has been detailed with regard to the sorting method. We present a new retrospective gating technique with sorting based on the amplitude of the motion trace. This method is compared to previously developed methods that sort based on phase. A 16-slice CT scanner (Sensation 16, Siemens Medical Solutions, Erlangen, Germany) was used to acquire images of two phantoms on a motion platform moving in two dimensions. The motion was monitored using a strain gauge inserted inside an adjustable belt. A 180 degrees interpolation was used for reconstruction after gating. Significant improvement using the amplitude-sorting technique was observed, particularly when testing nonperiodic motion functions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An optical flow based method for improved reconstruction of 4D CT data sets acquired during free breathing.

Respiratory motion degrades anatomic position reproducibility and leads to issues affecting image acquisition, treatment planning, and radiation delivery. Four-dimensional (4D) computer tomography (CT) image acquisition can be used to measure the impact of organ motion and to explicitly account for respiratory motion during treatment planning and radiation delivery. Modern CT scanners can only ...

متن کامل

Lung Deformation Estimation and Four-dimensional CT Lung Reconstruction1

Rationale and Objectives. Four-dimensional (4D) computed tomography (CT) can be used in radiation treatment planning to account for respiratory motion. Current 4D CT techniques have limitations in either spatial or temporal resolution. In addition, most of these techniques rely on auxiliary surrogates to relate the time of the CT scan to the patient’s respiratory phase. We propose a 4D CT metho...

متن کامل

Evaluation of 4D CT acquisition methods designed to reduce artifacts

Four-dimensional computed tomography (4D CT) is used to account for respiratory motion in radiation treatment planning, but artifacts resulting from the acquisition and postprocessing limit its accuracy. We investigated the efficacy of three experimental 4D CT acquisition methods to reduce artifacts in a prospective institutional review board approved study. Eighteen thoracic patients scheduled...

متن کامل

The Efficiency of Respiratory-gated 18F-FDG PET/CT in Lung Adenocarcinoma: Amplitude-gating Versus Phase-gating Methods

Objective(s): In positron emission tomography (PET) studies, thoracic movement under free-breathing conditions is a cause of image degradation. Respiratory gating (RG) is commonly used to solve this problem. Two different methods, i.e., phase-gating (PG) and amplitude-gating (AG) PET, are available for respiratory gating. It is important to know the strengths and weaknesses of both methods when...

متن کامل

Evaluation of two synchronized external surrogates for 4D CT sorting

The purpose of this study was to quantify the performance and agreement between two different external surrogate acquisition systems: Varian's Real-Time Position Management (RPM) and Philips Medical Systems' pneumatic bellows, in the context of waveform and 4D CT image analysis. Eight patient displacement curves derived from RPM data were inputted into a motion platform with varying amplitudes ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2006