Detection of gamma-hydroxybutyrate in hair: validation of GC-MS and LC-MS/MS methods and application to a real case.

نویسندگان

  • Elisabetta Bertol
  • Antonina Argo
  • Paolo Procaccianti
  • Fabio Vaiano
  • Maria Grazia Di Milia
  • Sandra Furlanetto
  • Francesco Mari
چکیده

A gas chromatography-mass spectrometry (GC-MS) and a liquid chromatography tandem mass spectrometry (LC-MS/MS) method were validated for quantifying endogenous and exogenous hair concentrations of gamma-hydroxybutyrate (GHB). The GC-MS method is based on overnight extraction of 25 mg hair in NaOH at 56 °C, liquid/liquid extraction in ethylacetate and trimethylsylil derivatization; analysis is by electron ionization and single ion monitoring of three ions. The LC-MS/MS method entails a rapid digestion of 25 mg hair with NaOH at 75 °C for 40 min, liquid/liquid extraction in ethylacetate and reconstitution of the extract in the LC mobile phase; negative ion electrospray ionization and multiple reaction monitoring (MRM) analysis are employed for the LC-MS/MS detection. In both cases, GHB-d6 is used as an internal standard. The endogenous amount in "blank" hair are estimated by the standard addition method. Limits of detection are 0.4 and 0.5 ng/mg for GC-MS and LC-MS/MS respectively, while the limit of quantification (LOQ) is 0.6 ng/mg for both methods; the GC-MS method proved to be linear in the range 1-50 ng/mg whereas linearity was demonstrated from 0.6 to 50 ng/mg for the LC-MS/MS; imprecision and inaccuracy were always lower than 23% for quality controls samples. The two methods were applied to a real case of a man addicted to GHB; the drug concentration in segments from 17 cm hair strand well correlated with self-reported use of GHB in different periods of his life. Performances of the two methods were similar.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Method validation of methotrexate in human plasma by LC-MS technique in patients with brain tumor.

Background and aims: A selective and sensitive high performance liquid chromatography-electrospray ionization mass spectrometry method has been established for determination of methotrexate in human plasma. Methods: Methotrexate was extracted from plasma with acetonitrile. The mobile phase consisted of acetonitrile-water-formic acid 74: 25: 1(v/v). Twenty...

متن کامل

Validation of the analysis method of 25 pesticide residues in rice using LC-MS/MS device (liquid chromatography-mass spectrometry)

Introduction: In recent years, due to the increase in the use of pesticides in agricultural products and its entry into the human food chain, there has been an increase in concerns about the health of food among people. Therefore, the purpose of conducting this research is to validate the analysis method. 25 pesticide residues in rice using LC-MS/MS. Methods: In this research, a simultaneous an...

متن کامل

Validation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS

Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...

متن کامل

Analysis of drugs of abuse in hair by automated solid-phase extraction, GC/EI/MS and GC ion trap/CI/MS.

In our laboratory, analysis of human hair for the detection of drugs of abuse was first performed in 1995. Initially, requests for hair analysis were few, and it is only since 1997 that these analyses have become routine. As demand grew, we developed an automatic solid-phase extraction method; the use of a robot ASPEC allowed us to drop certain fastidious manipulations, and to treat a large num...

متن کامل

[Applicability of GC, GC/MS and liquid chromatography with tandem mass spectrometry to screening for 140 pesticides in agricultural products].

The applicability of GC, GC/MS and liquid chromatography with tandem mass spectrometry (LC/MS/MS) to screening for 140 pesticides in agricultural products was examined. Validation of multi-residue screening methods for the determination of 88 pesticides in 12 crops (asparagus, cauliflower, burdock, carrot, broccoli, spinach, matsutake mushroom, orange, soybean, sesame, millet and tea) was done ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of pharmaceutical and biomedical analysis

دوره 70  شماره 

صفحات  -

تاریخ انتشار 2012