A cause of discrepancy between values for urinary protein as assayed by the Coomassie Brilliant Blue G-250 method and the sulfosalicylic acid method.

نویسندگان

  • K S Shiba
  • K Kanamori
  • T Harada
  • M Nakao
  • K Nakajima
  • T Kodaira
  • H Nakagawa
چکیده

In simultaneous assays of urinary proteins by the Coomassie Brilliant Blue G-250 (CBB) and the sulfosalicylic acid (SSA) methods, we noticed that about 18% of samples showed about twice higher protein values by the former method than by the latter. Some urinary proteins are soluble in SSA and react with CBB. Examinations with sodium dodecyl sulfate/polyacrylamide gel electrophoresis showed that these proteins migrated in 13 protein bands having relative molecular masses ranging from 15 000 to 230 000. The protein corresponding to the most intensely stained band in urine samples from the patients studied (with malignant tumors, renal disorders, etc.) had an Mr of 45 000; that in the pattern for healthy subjects had an Mr of 94 000. The former was identified as alpha 1-acid glycoprotein, the latter as Tamm-Horsfall mucoprotein.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Six methods for determining urinary protein compared.

Inter-laboratory surveys have shown that "routine methods" of urinary protein determination are often unsatisfactory. Therefore, we compared six frequently used methods for determination of protein in urine with respect to linearity, within-batch and between-batch precision, comparative bias, and practicability. We assayed dilutions of human and bovine albumin and serum, and fresh and lyophiliz...

متن کامل

Chemical Synthesis of Zinc Oxide Nanoparticles and Its Application of Dye Decolourization

   In the present study, various size of Zinc Oxide Nanoparticles (ZnO NPs) was synthesized via Sol-gel method. The photocatalytic activity of the synthesized ZnO NPs was investigated for the Decolourization of three different colored dyes viz. Congo Red, Acid Blue 9 and Coomassie Brilliant Blue R-250 under UV lamp. Zinc Chloride (Zncl2) and Sodium Hydroxide (NaOH) were ...

متن کامل

Criticism of the use of Coomassie Brilliant Blue G-250 for the quantitative determination of proteins.

The quantitative determination of proteins in biological fluids, using Coomassie Brilliant Blue G-250, was evaluated. Compared with the biuret method, the Coomassie Blue G-250 method needs a much shorter time for analysis and has a greater sensitivity. The sensitivity of the dye for albumin is significantly greater than for globulins. The standard curves for the biuret method are more linear th...

متن کامل

Is standardization more important than methodology for assay of total protein in cerebrospinal fluid?

Four manual micromethods for protein determination, two turbidimetric (trichloroacetic and sulfosalicylic acid-sodium sulfate) and two colorimetric (Lowry and Coomassie Brilliant Blue--sodium dodecyl sulfate, CBB-SDS) were used to compare the standard curves for total protein (0.30 to 3 g/L) produced with three reference materials: bovine serum albumin, human serum albumin, and diluted human se...

متن کامل

Total protein determined in human breast milk by use of coomassie brilliant blue and centrifugal analysis.

This simple method of centrifugal analysis for total protein in human breast milk is based on the change in the wavelength of the absorbance maximum of Coomassie Brilliant Blue G-250 when the dye is bound to protein. Within-run and between-day CVs were 3.8% and 4.8%, respectively. Compared with a micro-Kjeldahl method for determination of total nitrogen, the coefficient of correlation was 0.99.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 31 7  شماره 

صفحات  -

تاریخ انتشار 1985