Immunological evaluation of polystyrene and poly(ether imide) cell culture inserts with different roughness.

نویسندگان

  • Toralf Roch
  • Anne Krüger
  • Karl Kratz
  • Nan Ma
  • Friedrich Jung
  • Andreas Lendlein
چکیده

For the successful clinical and biological application of polymers, their interaction with cells, tissues, and body fluids has to be well characterized. In order to investigate how the physical, chemical, and mechanical properties of candidate biomaterials influence cell behaviours, the testing sample is usually placed in commercially available cell culture plates. Thus, not only the testing sample itself but also the culture dish material might influence the cell behaviour. Therefore, an insert system was created to exclude this influence and allow investigations of the testing material solely. In this study micropatterned inserts prepared from polystyrene (PS) as well as from poly(ether imide) (PEI) with three different roughness levels of i) Rq = 0.29 μm (PS) and 0.23 μm (PEI); ii) Rq = 3.47 μm (PS) and 3.92 μm (PEI); and iii) Rq = 22.16 μm [corrected] (PS) and 22.65 μm (PEI) were explored with regard of their immuno-compatibility including the determination of potential contaminations with endotoxins or other microbial products. The endotoxin levels of the inserts were determined to be less than 0.07 EU/mL, which is well below the U.S. Food and Drug Administration limit of 0.5 EU/mL and the survival of murine macrophages cultured in the inserts was not impaired. Activation of early immune mechanisms such as complement activation and the generation of reactive oxygen species could not be observed. All tested materials had no influence on the cytokine secretion from cells of whole human blood. The investigated inserts were immuno-compatible and apparently free of contaminations with microbial products. The roughness of the inserts had no stimulatory or inhibitory effect on early immune mechanisms. Conclusively, the 24-well plate insert systems introduced in this study allow investigating the interactions of tailored surface properties such as roughness with many other cell types, without the disadvantage of the standard commercially available culture vessels influencing the biomaterial testing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cytocompatibility testing of cell culture modules fabricated from specific candidate biomaterials using injection molding.

Most polymers used in clinical applications today are materials that have been developed originally for application areas other than biomedicine. Testing the cell- and tissue-compatibility of novel materials in vitro and in vivo is of key importance for the approval of medical devices and is regulated according to the Council Directive 93/42/EEC of the European communities concerning medical de...

متن کامل

Nanometric grafting of poly (N-isopropylacrylamide) onto polystyrene film by different doses of gamma radiation

Poly N-isopropylacrylamide was successfully grafted onto a polystyrene cell culture dish by gamma ray. In this study, the effect of a radiation dose (radiation absorbed dosages of 10, 20, 30, 40 KGy) under appropriate temperature and grafting conditions was investigated. The FTIR analysis showed the existence of the graft PNIPAAm on the substrate. The optimal value of the dose for grafting was ...

متن کامل

Nanometric grafting of poly (N-isopropylacrylamide) onto polystyrene film by different doses of gamma radiation

Poly N-isopropylacrylamide was successfully grafted onto a polystyrene cell culture dish by gamma ray. In this study, the effect of a radiation dose (radiation absorbed dosages of 10, 20, 30, 40 KGy) under appropriate temperature and grafting conditions was investigated. The FTIR analysis showed the existence of the graft PNIPAAm on the substrate. The optimal value of the dose for grafting was ...

متن کامل

Viability and function of primary human endothelial cells on smooth poly(ether imide) films.

Poly(ether imide) (PEI) is being explored as potential biomaterial for cardiovascular applications. Different studies showed that human umbilical venous endothelial cells (HUVEC) are able to adhere and proliferate on PEI membranes (R(q) = 13.20 ± 1.58 nm). A recently published study revealed evidence for much lower platelet adhesion on very smooth PEI-films (R(q) = 2.37 ± 1.40 nm). Therefore, w...

متن کامل

Implant Materials Generate Different Peri-implant Inflammatory Factors

STUDY DESIGN An in vitro study examining factors produced by human mesenchymal stem cells on spine implant materials. OBJECTIVE The aim of this study was to examine whether the inflammatory microenvironment generated by cells on titanium-aluminum-vanadium (Ti-alloy, TiAlV) surfaces is affected by surface microtexture and whether it differs from that generated on poly-ether-ether-ketone (PEEK)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical hemorheology and microcirculation

دوره 52 2-4  شماره 

صفحات  -

تاریخ انتشار 2012