Adaptive wavefront correction in two-photon microscopy using coherence-gated wavefront sensing.

نویسندگان

  • Markus Rueckel
  • Julia A Mack-Bucher
  • Winfried Denk
چکیده

The image quality of a two-photon microscope is often degraded by wavefront aberrations induced by the specimen. We demonstrate here that resolution and signal size in two-photon microcopy can be substantially improved, even in living biological specimens, by adaptive wavefront correction based on sensing the wavefront of coherence-gated backscattered light (coherence-gated wavefront sensing, CGWS) and wavefront control by a deformable mirror. A nearly diffraction-limited focus can be restored even for strong aberrations. CGWS-based wavefront correction should be applicable to samples with a wide range of scattering properties and it should be possible to perform real-time pixel-by-pixel correction even at fast scan speeds.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Snapshot coherence-gated direct wavefront sensing for multi-photon microscopy.

Deep imaging in turbid media such as biological tissue is challenging due to scattering and optical aberrations. Adaptive optics has the potential to compensate the tissue aberrations. We present a wavefront sensing scheme for multi-photon scanning microscopes using the pulsed, near-infrared light reflected back from the sample utilising coherence gating and a confocal pinhole to isolate the li...

متن کامل

Adaptive optical two-photon microscopy using autofluorescent guide stars.

We demonstrate a fast, direct wavefront-sensing method for dynamic in vivo adaptive optical two-photon microscopy. By using a Shack-Hartmann wavefront sensor and open-loop control, the system provides high-speed wavefront measurement and correction. To measure the wavefront in the middle of a Drosophila embryo at early stages, autofluorescence from endogenous fluorophores in the yolk were used ...

متن کامل

Adaptive optics two photon microscopy with direct wavefront sensing using autofluorescent guide-stars

A fast direct wavefront sensing method for dynamic in-vivo adaptive optical two photon microscopy has demonstrated. By using the direct wavefront sensing and open loop control, the system provides high-speed wavefront measurement and correction. To measure the wavefront in the middle of a Drosophila embryo at early stages, autofluorescence from endogenous fluorophores in the yolk were used as r...

متن کامل

Coherence-Gated Sensorless Adaptive Optics Multiphoton Retinal Imaging

Multiphoton microscopy enables imaging deep into scattering tissues. The efficient generation of non-linear optical effects is related to both the pulse duration (typically on the order of femtoseconds) and the size of the focused spot. Aberrations introduced by refractive index inhomogeneity in the sample distort the wavefront and enlarge the focal spot, which reduces the multiphoton signal. T...

متن کامل

Motivation for a coherence gated wavefront sensor (CG)-SH/WFS

Shack–Hartmann wavefront sensors (SH-WFS) have little sensitivity in depth and hence are unsuitable for microscopy and are limited for retinal imaging. We demonstrate the first direct Shack–Hartmann measurement of wavefront originating from a multiple-layer target, in the presence of significant stray reflections that render a standard SH-WFS inoperable. A coherence-gate SH-WFS is implemented b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Proceedings of the National Academy of Sciences of the United States of America

دوره 103 46  شماره 

صفحات  -

تاریخ انتشار 2006