Ion/molecule reactions, mass spectrometry and optical spectroscopy in a linear ion trap

نویسندگان

  • M. Welling
  • H. A. Schuessler
چکیده

A linear-geometry, radio-frequency, quadrupole ion trap has been developed to generate, purify, accumulate and study atomic and molecular ions in the gas phase. By employing a trap-based system, both reactant and product ions can be stored for significant time periods, which can both enhance the efficiency of gas-phase reaction processes and create an environment to observe collision products after vibrational and rotational excitations have had time to relax. Relaxation occurs via viscous cooling with a dilute buffer gas or via laser cooling. Furthermore, the setup is particularly useful for performing optical spectroscopy on the trapped ions. Atomic and molecular ovens are used to generate thermal beams of neutral species, which are then ionized by electron bombardment. The ions can be trapped, or they can be collided with neutral molecules (e.g. C60) under well defined experimental conditions. The collision energies are variable over a range from nearly 0 to 200 eV. This feature makes possible studies of complex formation, charge transfer and collision-induced fragmentation as a function of kinetic energy. A wide range of masses of up to 4000 u can be stored and manipulated with this apparatus. Two mass spectrometric techniques for the analysis of trapped ionic species are presented. In one method, parametric excitation of the secular motion is used to generate mass spectra with resolutions as high as 1 part in 800 with a simple experimental setup. The second method is capable of quickly generating mass spectra over the entire range of trapped masses, but has only moderate resolution. These spectra are generated by linearly sweeping the rf-trapping voltage to zero and detecting ions as their trap depth falls below a threshold value. In the trapping volume, which is 10 cm in length and 200 #m in diameter, 106 ions can be loaded and stored, corresponding to an ion density above 108 cm -3. Such densities facilitate spectroscopy of the stored ions. Both laser-induced fluorescence and photodissociation measurements have been carried out with a cw laser system providing near-infrared, visible, and ultraviolet beams. Absolute, total cross-sections and branching ratios of the photodissociation of MgC~0 have been measured. © 1998 Elsevier Science B.V.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

A Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study

     A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...

متن کامل

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

Ion/molecule reactions for detecting ammonia using miniature cylindrical ion trap mass spectrometers.

Gaseous ammonia, a common toxic industrial compound, is not detected readily in ion trap mass spectrometers because its molecular ion falls below the low-mass cutoff (~m/z 40) normally used when examining organic compounds. Instead, reactions of ammonia with halobenzene radical cations were used with internal electron ionization in two cylindrical ion trap miniature mass spectrometers to create...

متن کامل

Identification of 2-aminothiazolobenzazepine metabolites in human, rat, dog, and monkey microsomes by ion-molecule reactions in linear quadrupole ion trap mass spectrometry.

2-Aminothiazolobenzazepine (2-ATBA), 7-[(1-methyl-1H-pyrazol-4-yl)methyl]-6,7,8,9-tetrahydro-5H-[1,3]thiazolo[4,5-h][3]benzazepin-2-amine, is a D2 partial agonist that has demonstrated antipsychotic effects in a rodent in vivo efficacy model. The metabolite profile showed that 2-ATBA is mainly metabolized by oxidation. However, identification of the oxidation site(s) in the 2-aminothiazole grou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003