Secondary electrospray ionization-ion mobility spectrometry for explosive vapor detection.

نویسندگان

  • Maggie Tam
  • Herbert H Hill
چکیده

The unique capability of secondary electrospray ionization (SESI) as a nonradioactive ionization source to detect analytes in both liquid and gaseous samples was evaluated using aqueous solutions of three common military explosives: cyclo-1,3,5-trimethylene-2,4,6-trinitramine (RDX), nitroglycerin (NG) and pentaerythritol tetranitrate (PETN). The adducts formed between the compounds and their respective dissociation product, RDX.NO(2)(-), NG.NO(3)(-), and PETN.NO(3)(-), gave the most intense signal for the individual compound but were more sensitive to temperature than other species. These autoadducts were identified as RDX.NO(2)(-), NG.NO(3)(-), and PETN.NO(3)(-) and had maximum signal intensity at 137, 100, and 125 degrees C, respectively. The reduced mobility values of the three compounds were constant over the temperature range from 75 to 225 degrees C. The signal-to-noise ratios for RDX, NG, and PETN at 50 mg L(-1) in methanol-water were 340, 270, and 170, respectively, with a nominal noise of 8 +/- 2 pA. In addition to the investigation of autoadduct formation, the concept of doping the ionization source with nonvolatile adduct-forming agents was investigated and described for the first time. The SESI-IMS detection limit for RDX was 116 microg L(-1) in the presence of a traditional volatile chloride dopant and 5.30 microg L(-1) in the presence of a nonvolatile nitrate dopant. In addition to a lower detection limit, the nitrate dopant also produced a greater response sensitivity and a higher limit of linearity than did the traditional volatile chloride dopant.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Secondary electrospray ionization ion mobility spectrometry/mass spectrometry of illicit drugs.

A secondary electrospray ionization (SESI) method was developed as a nonradioactive ionization source for ion mobility spectrometry (IMS). This SESI method relied on the gas-phase interaction between charged particles created by electrospray ionization (ESI) and neutral gaseous sample molecules. Mass spectrometry (MS) was used as the detection method after ion mobility separation for ion identi...

متن کامل

Analysis of explosives using electrospray ionization/ion mobility spectrometry (ESI/IMS).

The analysis of explosives with ion mobility spectrometry (IMS) directly from aqueous solutions was shown for the first time using an electrospray ionization technique. The IMS was operated in the negative mode at 250 degrees C and coupled with a quadrupole mass spectrometer to identify the observed IMS peaks. The IMS response characteristics of trinitrotoluene (TNT), 2,4-dinitrotoluene (2,4-DN...

متن کامل

Secondary ionization of chemical warfare agent simulants: atmospheric pressure ion mobility time-of-flight mass spectrometry.

For the first time, the use of a traditional ionization source for ion mobility spectrometry (radioactive nickel ((63)Ni) beta emission ionization) and three alternative ionization sources (electrospray ionization (ESI), secondary electrospray ionization (SESI), and electrical discharge (corona) ionization (CI)) were employed with an atmospheric pressure ion mobility orthogonal reflector time-o...

متن کامل

DETECTION AND MEASUREMENT OF ACETONE IN THE BREATH OF DIABETICS BY ION MOBILITY SPECTROMETRY METHOD

Background: The ion mobility spectrometry (IMS) is an analytical technique that is widely used due to its high sensitivity and speed for the detection of ionized molecules in gas phase and under atmospheric pressure. Breath analysis is a new method for obtaining information about person's clinical conditions that is considered by researchers. Human exhaled air contains a variety of components s...

متن کامل

Characterizing Bacterial Volatiles using Secondary Electrospray Ionization Mass Spectrometry (SESI-MS)

Secondary electrospray ionization mass spectrometry (SESI-MS) is a method developed for the rapid detection of volatile compounds, without the need for sample pretreatment. The method was first described by Fenn and colleagues and has been applied to the detection of illicit drugs and explosives, the characterization of skin volatiles, and the analysis of breath. SESI ionization occurs by proto...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 76 10  شماره 

صفحات  -

تاریخ انتشار 2004