Delivery of iloprost inhalation solution with the HaloLite, Prodose, and I-neb Adaptive Aerosol Delivery systems: an in vitro study.

نویسندگان

  • Robert E Van Dyke
  • Kurt Nikander
چکیده

BACKGROUND Iloprost (Ventavis) inhalation solution is approved in doses of 2.5 microg and 5.0 microg for treatment of pulmonary arterial hypertension (World Health Organization group I) in patients with New York Heart Association class III or IV symptoms, delivered with 2 Adaptive Aerosol Delivery (AAD) systems: Prodose and I-neb. The HaloLite device was the first-generation AAD system used in the clinical delivery of inhaled iloprost, and I-neb is the third-generation system. OBJECTIVE Study the in vitro performance of the HaloLite, Prodose, I-neb, in terms of mass median aerodynamic diameter (MMAD), fine-particle fraction (FPF, percent of aerosol droplets < 4.7 microm), and inhaled mass of iloprost. METHODS To analyze the MMAD and FPF, we collected the aerosol from each device with a cascade impactor. Because the devices are breath-actuated, airflow was regulated with flow-control valves to create inhalation and exhalation. To measure the inhaled mass of iloprost we used a breathing simulator with a filter system between the simulator and the device, and quantified the captured aerosol with iloprost-specific chromatography. RESULTS With the HaloLite, Prodose, and I-neb, respectively: the MMADs were 1.4 microm, 1.7 microm, and 2.1 microm; the FPFs were 91%, 82%, and 82%. The inhaled mass with the 2.5-microg dose ranged from 2.8 microg to 2.9 microg. The inhaled mass with the 5.0-microg dose ranged from 4.8 microg to 5.2 microg. CONCLUSION The HaloLite, Prodose, and I-neb AAD systems have comparable MMADs, FPFs, and inhaled mass with iloprost.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The safety and pharmacokinetics of rapid iloprost aerosol delivery via the BREELIB nebulizer in pulmonary arterial hypertension

The BREELIB nebulizer was developed for iloprost to reduce inhalation times for patients with pulmonary arterial hypertension (PAH). This multicenter, randomized, unblinded, four-part study compared inhalation time, pharmacokinetics, and acute tolerability of iloprost 5 µg at mouthpiece delivered via BREELIB versus the standard I-Neb nebulizer in 27 patients with PAH. The primary safety outcome...

متن کامل

In vitro characterization of the I-neb Adaptive Aerosol Delivery (AAD) system.

The in vitro characterization of device-related parameters such as the rate of aerosol output, total aerosol output, particle size, and fine particle fraction, is essential when assessing the potential performance of a nebulizer or making comparisons with other nebulizers as they are indicative of potential clinical performance. This article reviews a number of in vitro studies designed to char...

متن کامل

Antibacterial loaded Spray Dried Chitosan Polyelectrolyte Complexes as Dry Powder Aerosol for the Treatment of Lung Infections

Inhalation delivery of aerosolized antibacterials is preferred over conventional methods of delivery for targeting lung infection. The present study is concerned with the development and characterization of a novel, spray dried, aerosolized, chitosan polyelectrolyte complex (PEC) based microparticles containing antibacterials for the treatment of lung infections.Chitosan polyelectrolyte complex...

متن کامل

Antibacterial loaded Spray Dried Chitosan Polyelectrolyte Complexes as Dry Powder Aerosol for the Treatment of Lung Infections

Inhalation delivery of aerosolized antibacterials is preferred over conventional methods of delivery for targeting lung infection. The present study is concerned with the development and characterization of a novel, spray dried, aerosolized, chitosan polyelectrolyte complex (PEC) based microparticles containing antibacterials for the treatment of lung infections.Chitosan polyelectrolyte complex...

متن کامل

Pulmonary Drug Delivery Following Continuous Vibrating Mesh Nebulization and Inspiratory Synchronized Vibrating Mesh Nebulization During Noninvasive Ventilation in Healthy Volunteers.

BACKGROUND A breath-synchronized nebulization option that could potentially improve drug delivery during noninvasive positive pressure ventilation (NIPPV) is currently not available on single-limb circuit bilevel ventilators. The aim of this study was to compare urinary excretion of amikacin following aerosol delivery with a vibrating mesh nebulizer coupled to a single-limb circuit bilevel vent...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Respiratory care

دوره 52 2  شماره 

صفحات  -

تاریخ انتشار 2007