Use and performance of the Melody Transcatheter Pulmonary Valve in native and postsurgical, nonconduit right ventricular outflow tracts.
نویسندگان
چکیده
BACKGROUND Melody Transcatheter Pulmonary Valve (TPV) replacement therapy represents an important advance in congenital cardiovascular interventions. The off-label extension of the Melody TPV to patients with nonconduit outflow tracts (right ventricular outflow tract [RVOT]) has the potential to vastly expand the population of patients eligible to benefit from nonsurgical restoration of RVOT function. However, knowledge on the performance of the Melody TPV in this setting is limited. METHODS AND RESULTS This is a multicenter, retrospective review of the Melody TPV when placed in nonconduit RVOTs, in which at least a portion of the circumference was composed of native tissue. Five centers contributed data on 31 patients. The median age at implantation was 24 years (range, 7-66). At a median follow-up of 15 months, all patients were alive. No patient had greater than mild TPV insufficiency, and the median maximum instantaneous gradients across the RVOT was 23 mm Hg. Stent fracture occurred in 32%. Eight patients developed more than mild TPV obstruction, of whom 6 were associated with identified stent fracture. Three patients developed blood stream infections. There were 5 reinterventions in 3 patients, including 3 repeat TPV implantations and 2 TPV explantations. CONCLUSIONS Melody TPV implantation is feasible in selected patients with RVOTs comprised solely or predominantly native tissue and has the potential to expand the population of patients eligible to benefit from nonsurgical restoration of RVOT function. In early follow-up, valve competency seems preserved. The dominant mechanism of valve dysfunction seems to be related to stent fracture with recurrent obstruction. Additional data are necessary to better understand how to safely expand TPV therapy to this population.
منابع مشابه
Short-term performance of the transcatheter Melody valve in high-pressure hemodynamic environments in the pulmonary and systemic circulations.
BACKGROUND The Melody valve is approved for percutaneous pulmonary valve replacement in dysfunctional right ventricular outflow tracts. The function of this valve when subjected to high-pressure loads in humans is unknown. The aim of this study was to describe the immediate and short-term results of Melody valves implanted in a high-pressure environment. METHODS AND RESULTS Definitions of a h...
متن کاملThe future of transcatheter pulmonary valvulation.
Percutaneous pulmonary valve implantation now has a key role in the setting of dysfunctional right ventricle-to-pulmonary artery conduits or failing bioprosthetic pulmonary valves. However, despite the excellent results obtained with the two devices available currently (the Melody(®) valve [Medtronic Inc., Minneapolis, MN, USA] and the Edwards SAPIEN(®) valve [Edwards Lifesciences, Irvine, CA, ...
متن کاملImages and Case Reports in Interventional Cardiology Branch Pulmonary Artery Jailing With a Bare Metal Stent to Anchor a Transcatheter Pulmonary Valve in Patients With Patched Large Right Ventricular Outflow Tract
Although transcatheter pulmonary valve replacement using the Melody valve (Medtronic Inc, Minneapolis, MN) has become widely adopted, it has only been formally studied in patients with right ventricle–to–pulmonary artery conduits 22 mm in diameter.1,2 Such patients compose only a small proportion of individuals with right ventricular outflow tract (RVOT) dysfunction, and there is interest and p...
متن کاملBranch pulmonary artery jailing with a bare metal stent to anchor a transcatheter pulmonary valve in patients with patched large right ventricular outflow tract.
Although transcatheter pulmonary valve replacement using the Melody valve (Medtronic Inc, Minneapolis, MN) has become widely adopted, it has only been formally studied in patients with right ventricle–to–pulmonary artery conduits 22 mm in diameter.1,2 Such patients compose only a small proportion of individuals with right ventricular outflow tract (RVOT) dysfunction, and there is interest and p...
متن کاملMelody valve implant within failed bioprosthetic valves in the pulmonary position: a multicenter experience.
BACKGROUND Transcatheter pulmonary valve implantation using the Melody valve has emerged as an important therapy for the treatment of postoperative right ventricular outflow tract dysfunction. Melody-in-bioprosthetic valves (BPV) is currently considered an off-label indication. We review the combined experience with transcatheter pulmonary valve implantation within BPVs from 8 centers in the Un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Cardiovascular interventions
دوره 7 3 شماره
صفحات -
تاریخ انتشار 2014