Mid-term results of interventional closure of patent foramen ovale with the Occlutech Figulla® Flex II Occluder

نویسندگان

  • Jonas Neuser
  • Muharrem Akin
  • Udo Bavendiek
  • Tibor Kempf
  • Johann Bauersachs
  • Julian D. Widder
چکیده

BACKGROUND Patients with a patent foramen ovale (PFO) who suffered from stroke, TIA or peripheral paradoxical embolism are at substantial risk for recurrent neurologic events and in need for secondary prevention. Interventional closure of PFO has been performed for over 20 years. Numerous devices have been developed and used for treatment. We investigated PFO closure with the third generation Occlutech Figulla® Flex II Occluder device. METHODS Between 2012 and 2015 57 patients (mean age 47.3 ± 1.5 years) who had suffered from a thromboembolic event of unknown cause underwent transcatheter PFO closure with the Occlutech Figulla® Flex II Occluder at our department. 68.4 % of all patients had suffered from cryptogenic stroke, while TIA had occurred in 28.1 %. Almost all patients were diagnosed with an atrial septum aneurysm (90.9 %) and a severe right-to-left shunt grade 3: >20 microbubbles (92.0 %). Follow-up was done 6 months post intervention by clinical examination and transesophageal contrast echocardiography. RESULTS No major periprocedural or in-hospital complication occurred. Closure was sufficient with no residual right-to-left shunt in 94.4 % of all patients at 6 months post implantation and only minimal residual shunt in three cases. There were no thrombotic formations associated to the occluder device. Atrial fibrillation occurred in one patient and a recurrent cerebral ischemic event was seen in one patient, who suffered from another TIA. CONCLUSIONS The Occlutech Figulla® Flex II Occluder device and its delivery system is safe and provides sufficient closure of PFO in patients who suffered from cryptogenic stroke, TIA or paradoxical peripheral embolism.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Occlutech Figulla PFO and ASD occluder: a new nitinol wire mesh device for closure of atrial septal defects.

BACKGROUND We investigated the safety, feasibility and efficacy of the Occlutech devices for patent foramen ovale (PFO) and atrial septal defect (ASD) closure in a prospective trial. METHODS The retention discs of the PFO device (23 x 25 mm, 27 x 30 mm) are connected by a 3 mm waist in the center with only one right atrial side central pin. The left atrial disc is produced either with a singl...

متن کامل

Echocardiographic findings in simple and complex patent foramen ovale before and after transcatheter closure.

AIMS Percutaneous closure of patent foramen ovale (PFO) in cryptogenic cerebrovascular events is an alternative to medical therapy. The interpretation of residual shunts after implantation of different devices for PFO with different morphologies is controversial. METHODS AND RESULTS Transcatheter PFO closure was performed in 123 patients with a history of ≥1 paradoxical embolism using three d...

متن کامل

Long-term follow-up after percutaneous closure of patent foramen ovale with Amplatzer PFO Occluder: a single center experience.

INTRODUCTION Patent foramen ovale (PFO) is associated with the occurrence of cryptogenic strokes, transient neurological ischemic attacks (TIA) and migraine. Therefore despite the recent ambiguous results of prospective controlled trials, percutaneous closure of PFO is still performed in many centers. AIM To evaluate the safety and effectiveness of percutaneous PFO closure in the prevention o...

متن کامل

Transvenous Closure of Patent Foramen Ovale: Preliminary Results with a New Self-Expanding Nitinol Wire Mesh in a Swine Model

Objectives. The transvascular closure of patent foramen ovale (PFO) with self-expanding devices carries the risk of left atrial thrombus formation related to material protruding into the left atrium. Thus, we developed a novel device with flat left atrial disc geometry. We evaluated feasibility, handling, and biocompatibility in a porcine animal model. Methods. Implantation of an Occlutech Figu...

متن کامل

A comparison of the in vivo neoendothelialization and wound healing processes of three atrial septal defect occluders used during childhood in a nonrandomized prospective trial

OBJECTIVE We prospectively investigated the neoendothelialization of transcatheter secundum atrial septal defect (ASD) closure in children receiving one of three different occluders. METHODS Transcatheter ASD closure was performed for 44 children. The patients were divided into three groups: group I: Amplatzer, group II: Lifetech CeraFlex, and group III: Occlutech Figulla Flex II septal occlu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2016