Microbubble potentiated ultrasound as a method of stroke therapy in a pig model: preliminary findings.

نویسندگان

  • William C Culp
  • Eren Erdem
  • Paula K Roberson
  • Muhammad M Husain
چکیده

PURPOSE Low-frequency ultrasound (LFUS) with intraarterial or intravenous microbubbles can recanalize thrombosed dialysis grafts and arteries. A similar method for declotting intracranial arteries in an animal model has been developed. MATERIALS AND METHODS Swine underwent selective cerebral angiography, and 1 mL of 2-6 hour old clot was placed in one ascending pharyngeal artery and rete mirabile. This occluded the primary brain blood supply from the rete mirabile in the base of the skull. Human albumin octafluoropropane microbubbles were injected through the same catheter in 0.5-1.0-mL doses for a total of 4.5 mL in 21 minutes. Transcutaneous pulsed-wave 1-MHz ultrasound was administered through a temporal approach using 2.2 W/cm(2). Repeated angiography was performed through 24 minutes. Saline controls underwent an identical process on the opposite side. Declotting was graded on a scale of 0-4, and flow used the 0-3 thrombolysis in myocardial infarction (TIMI) scale. Success was defined as declotting of grade >/= 3 (>70% clearing) with flow of >/= 2. RESULTS Seven pigs received 14 declotting sequences. Average clot age was 217 minutes. Average declotting score was 3.1, and flow was 2.1 for microbubbles and 1.4 and 0.1 for saline controls, P =.016 in each. Success occurred with microbubbles in six of seven attempts and in controls in zero of seven attempts, P =.031. CONCLUSIONS LFUS with microbubble augmentation rapidly lyses intracranial clot and restores flow at ultrasound ranges similar to those required in humans. Further development of this possible acute stroke therapy is justified.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling and investigating the effect of ultrasound waves pressure on the microbubble oscillation dynamics in microvessels containing an incompressible fluid (Research Article)

Understanding the dynamics of microbubble oscillation in an elastic microvessel is important for the safe and effective applications of ultrasound contrast agents in imaging and therapy. Numerical simulations based on 2D finite element model are performed to investigate the effect of acoustic parameters such as pressure and frequency on the dynamic interaction of the fluid-blood-vessel system. ...

متن کامل

Blood Brain Barrier Disruption by Focused Ultrasound and Microbubbles: A Numerical Study on Mechanical Effects

Introduction: Microbubbles are widely used as contrast agent in diagnostic ultrasound. Recently they have shown good potential for applications in the therapeutic field such as drug delivery to the brain. Recent studies have shown focused ultrasound in conjunction with injected micro-bubbles could temporarily disrupt blood-brain barrier and let therapeutic agents transport into...

متن کامل

Ultrasound microbubble destruction imaging in acute middle cerebral artery stroke.

BACKGROUND AND PURPOSE Cerebral perfusion imaging in acute stroke assists in determining the subtype and the severity of ischemia. Recent studies in perfusion models and in healthy volunteers have shown that ultrasound perfusion imaging based on microbubble destruction can be used to assess tissue perfusion. We applied ultrasound microbubble destruction imaging (MDI) to identify perfusion defic...

متن کامل

Attenuation correction in ultrasound contrast agent imaging: elementary theory and preliminary experimental evaluation.

Progress in imaging and quantification of tissue perfusion using ultrasound (US) and microbubble contrast agents has been undermined by the lack of an effective automatic attenuation correction technique. In this article, an elementary model of the US attenuation processes for microbubble contrast enhanced imaging is developed. In the model, factors such as nonlinear bubble scattering, nonlinea...

متن کامل

The interaction of microbubbles with high intensity pulsed ultrasound

High intensity pulsed ultrasound when interacting with microbubble contrast agents is potentially useful for biomedical applications such as drug delivery, cancer treatment and tissue ablation. To establish a fundamental understanding of the interaction between a microbubble with a sound wave, numerical simulations are performed using the Boundary Element Method (BEM). Bubble dynamics in terms ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of vascular and interventional radiology : JVIR

دوره 14 11  شماره 

صفحات  -

تاریخ انتشار 2003