Measurement of Partial Discharges in High Voltage Equipment

نویسنده

  • Yanko Konstantinov Sheiretov
چکیده

In this thesis I investigate the possibility of electrically detecting partial discharges in high voltage equipment. Partial discharges are small events that occur in insulation in the presence of high electric field intensity and manifest themselves as pulses of current superimposed on the high voltage lines. They carry important information about the condition and operation of such equipment. Monitoring their characteristic features makes it possible to extract this information. I work on the theoretical design of a system which in response to a current pulse produces a waveform convenient to digitize. In addition I build a physical system based on this model and measure its characteristics. The underlying idea behind this system is adapted from a nuclear physics problem of counting high-energy particles. Thesis Supervisor: Dr. Chathan M. Cooke Title: Principal Research Engineer, Lecturer EECS

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inductively coupled probe for the measurement of partial discharges.

Partial discharges are a transient phenomena whose measurement is remarkably important for electrical equipment diagnosis and maintenance. These discharges appear in the measurement circuit as very narrow current pulses of some nanoseconds. Therefore, discharge pulse detection is a particularly difficult problem, especially because they are superposed on the high voltage waveforms that cause th...

متن کامل

Characterization of Medium Voltage Equipment Ageing by Monitoring of Partial Discharges Chemical and Acoustical Emission

During the ageing of in-service medium voltage equipment, electrical losses are mainly due to partial discharges. These partial discharges can lead to the electrical failure of industrial equipment [1]. Partial discharges include (i) bulk discharges occurring in insulating material voids, (ii) corona discharges affecting or not the insulator and (iii) surface discharges developing on an insulat...

متن کامل

Using the Expert Systems in the Evaluation of the State of High Voltage Insulation Systems of Electrical Machines

Expert systems are used for evaluating the actual state and future behavior of insulating systems of high voltage electrical machines and equipment. Several rule-based expert systems have been developed in cooperation with top diagnostic workplaces in the Czech Republic for this purpose. The IZOLEX expert system evaluates diagnostic measurement data from commonly used off-line diagnostic method...

متن کامل

Detection of Partial Discharges Using Optelectronic Method

The insulation of the high voltage equipment is deteriorated due to the partial discharges (PDs). So it is required to monitor PDs continuously for prediction of insulation life, replacement time and early indication of outages of HV power equipment. In this work, an optical network is used to detect and measure the PDs in a model transformer.

متن کامل

Analysis and Location of Partial Discharges in Power Transformers by Means of Electrical Methods

Considering the number of failures in high voltage power transformers caused by problems in bushing and winding insulation, it is important to study means for diagnosing incipient failures, to avoid long unavailability periods and its consequences. The aim of this work is to study detection and measurement procedures, concerning the evaluation of position of partial discharge inside the transfo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006