Toward a digital camera to rival the human eye

نویسندگان

  • Orit Skorka
  • Dileepan Joseph
چکیده

All things considered, electronic imaging systems do not rival the human visual system despite notable progress over 40 years since the invention of the CCD. This work presents a method that allows design engineers to evaluate the performance gap between a digital camera and the human eye. The method identifies limiting factors of the electronic systems by benchmarking against the human system. It considers power consumption, visual field, spatial resolution, temporal resolution, and properties related to signal and noise power. A figure of merit is defined as the performance gap of the weakest parameter. Experimental work done with observers and cadavers is reviewed to assess the parameters of the human eye, and assessment techniques are also covered for digital cameras. The method is applied to 24 modern image sensors of various types, where an ideal lens is assumed to complete a digital camera. Results indicate that dynamic range and dark limit are the most limiting factors. The substantial functional gap, from 1.6 to 4.5 orders of magnitude, between the human eye and digital cameras may arise from architectural differences between the human retina, arranged in a multiple-layer structure, and image sensors, mostly fabricated in planar technologies. Functionality of image sensors may be significantly improved by exploiting technologies that allow vertical stacking of active tiers. © 2011 SPIE and IS&T. [DOI: 10.1117/1.3611015]

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of detecting and localizing radioactive source using image processing and computational geometry algorithms

We consider the problem of finding the localization of radioactive source by using data from a digital camera. In other words, the camera could help us to detect the direction of radioactive rays radiation. Therefore, the outcome could be used to command a robot to move toward the true direction to achieve the source. The process of camera data is performed by using image processing and computa...

متن کامل

Comparing The Power of the Intraoral Camera to the Digital Extraoral Camera in Diagnosis of Non metric Dental Morphologic Traits

Abstract Background and Aims :One of the method for studying nonmetric traits is intraoral photography pictures .The aim of this research is , Comparison of the power of the intraoral camera to a  Extraoral camera to diagnose of morphologic non metric traits. Materials and Methods:In this diagnostic  research we selected eligible samples ,among them at least 40 were without traits and 40 had ...

متن کامل

A Proposed Simple Teleradiology System Using a Digital Camera

Background & Aims: Teleradiology as an efficient way for avoiding unnecessary transfer of patients to special medical centers requires the images with digital format. However, in some developing countries, including Iran, imaging is being done using non digital devices. In such cases, changing analog images into digital ones can solve the problem. The method which is nowadays used for digita...

متن کامل

Diagnostic Accuracy of Digitized Images Using Different Resolution Settings of Digital Camera in Detection of Proximal Caries

Objective: When none of digital systems and scanners is accessible and it is essential to have digitized images of conventional radiographs, digital cameras can be used. The Aim of this study was to investigate whether digital images obtained by different resolutions of a digital camera are matched to the original radiographs in evaluation of caries. Methods: In this diagnostic accuracy in v...

متن کامل

مقایسه دقت تصاویر رادیوگرافی

Statement of Problem: Computer Sciences, in radiology, like other fields, is of high importance. It should also be noted that the accuracy of the technique and work conditions affects the radiographs information considerably. There for, in order to get more accurate diagnostic information, it seems necessary to investigate different digitized radiographic techniques and to compare them with the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • J. Electronic Imaging

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2011