Intravascular Ultrasound Balloon Catheter
نویسندگان
چکیده
Background Coronary stenting in conjunction with coronary angioplasty is a valuable tool for treatment of severe coronary dissection and is effective in reducing the frequency of restenoses. Evidence is increasing that the lumen gain within the stent is negatively correlated with the rate of subacute closures and restenoses. Since the assessment of radiolucent coronary stents and complex lumen morphologies by angiography is limited, we hypothesized that the use of a balloon catheter with integrated intravascular ultrasound (IVUS) facility for stent deployment and guidance of its expansion could improve the acute lumen gain without relevant procedural prolongation. Methods and Results Deployment of a single Palmaz-Schatz coronary stent with the combined imaging balloon catheter alone was successful in 18 of 20 patients eligible for this study. Corresponding measurements of minimal lumen diameter (MLD) by angiography and IVUS could be performed in 16 patients, revealing a close correlation between the two methods within the reference segments (3.10±0.38 and 3.08±0.43 mm, r=.79). Despite an adequate angiographic result in most patients after stent deployment, IVUS showed smaller MLD within the stented segment (2.15+0.23 mm) compared with angiography (2.63+0.26 mm, P<.0001) with a poor correlation (r=.27). To achieve IVUS criteria for optimal stent expansion (ratio of 0.9 between IVUS-assessed cross-sectional area of stent and reference segment), an average of three additional balloon inflations with higher pressure and/or a larger balloon diameter were performed without adverse effects in 15 of 16 patients who initially did not fulfill these criteria. This resulted in a significant increase in stent MLD to 2.63±0.27 mm (IVUS, P<.0001 versus initial MLD) and 2.89±0.32 mm (angiography, P<.0002 versus initial MLD) and a better correlation between the two methods (r=.60). The IVUS guidance led to a 40+15% increase of the minimal stent cross-sectional area with an additional time consumption of 21 minutes on average. Conclusions This study demonstrates the application of a combined imaging balloon catheter for delivery and ultrasound-guided expansion of Palmaz-Schatz coronary stents. IVUS offered a comprehensive insight into the stented coronary segments, revealing a substantial overestimation of stent dimensions by angiography. IVUS guidance led to a significant improvement of stent expansion. This additional lumen gain, which was not discernible by angiography in most patients, might result in a reduction of subacute stent thromboses as well as restenoses. (Circulation. 1994;90:1252-1261.)
منابع مشابه
Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions. In vivo comparison to cineangiography.
Tomographic imaging techniques such as ultrasound can provide important information in the evaluation of vascular anatomy. Recent technical advances have permitted fabrication of a small (1.83 mm), phased-array, intravascular ultrasonic imaging catheter capable of continuous real-time, cross-sectional imaging of blood vessels. We used this imaging catheter to compare intraluminal ultrasound wit...
متن کاملNew Phased-Array Ultrasound Imaging Catheter in the Assessment of Vascular Dimensions
uous real-time, cross-sectional imaging of blood vessels. We used this imaging catheter to compare intraluminal ultrasound with cineangiography in the measurement of vascular dimensions in animals and to assess the intraobserver and interobserver variability of the technique. Segmental deformation of vessel anatomy was produced by stenoses created with a tissue ligature or by balloon dilation. ...
متن کاملIntraluminal ultrasound imaging through a balloon dilation catheter in an animal model of coarctation of the aorta.
BACKGROUND Controversy still exists over the optimal balloon size, extent of vascular disruption, and long-term results of balloon dilation therapy for coarctation of the aorta. Intravascular ultrasound imaging has been used in patients with coronary artery disease to provide further insight into the anatomy of atherosclerotic lesions and the results of angioplasty and atherectomy. Initial obse...
متن کاملMorphological effects of coronary balloon angioplasty in vivo assessed by intravascular ultrasound imaging.
BACKGROUND Histological examination of the effects of balloon angioplasty have been described from in vitro experiments and a limited number of pathologic specimens. Intravascular ultrasound imaging permits real time cross-sectional observation of the effect of balloon dilation on the atherosclerotic plaque in vivo. METHODS AND RESULTS The morphological effects of coronary angioplasty were vi...
متن کاملIntravascular ultrasound cross-sectional arterial imaging before and after balloon angioplasty in vitro.
A prototype ultrasound imaging catheter was evaluated in vitro using 17 human atherosclerotic artery segments before and after balloon dilatation angioplasty. The catheter was 1.2 mm in diameter and incorporated a single 20-MHz ultrasound transducer to obtain cross-sectional images of the arterial lumen. In 15 of the 17 (88%) arteries, high quality images were obtained, which demonstrated clear...
متن کاملFocused in vivo delivery of plasmid DNA to the porcine vascular wall via intravascular ultrasound destruction of microbubbles.
BACKGROUND Safety concerns associated with drug-eluting stents have spurred interest in alternative vessel therapeutics following angioplasty. Microbubble contrast agents have been shown to increase gene transfection in vivo in the presence of ultrasound. OBJECTIVES/METHODS The purpose of this study was to determine whether an intravascular ultrasound (IVUS) catheter could mediate plasmid DNA...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005