BACKGROUND Some symptomatic degenerative conditions of the lumbar spine may be treated with spinal fusion if conservative treatment has failed. The minimally invasive technique of transforaminal lumbar interbody fusion (MIS TLIF) is increasingly used but has been found to generate increased radiation exposure to the patient and staff. Modern three-dimensional (3D) C-arm devices are capable of providing conventional two-dimensional fluoroscopic images (x-rays) as well as 3D image sets for intraoperative navigation. This study was designed to compare the radiation exposure between these two intraoperative imaging techniques in MIS TLIF procedures. METHODS This study is a randomized controlled trial. Forty participants scheduled to undergo monosegmental MIS TLIF will be recruited and randomly allocated to one of two groups with respect to the applied intraoperative imaging technique: conventional fluoroscopy (FLUORO group) and 3D fluoroscopy-based navigation combined with conventional fluoroscopy (NAV group). Furthermore, patients scheduled to undergo bisegmental MIS TLIF during the recruitment period for monosegmental MIS TLIF will be assessed for eligibility and will be randomly assigned separately. The primary endpoint is the radiation exposure to the surgeon and is measured by dosimeter readings. Secondary endpoints are the radiation exposure to the assistant surgeon, scrub nurse, anesthetist, patient, and C-arm as well as radiation exposure in relation to the body mass index of the patient. DISCUSSION Results of this randomized study will help to compare the radiation exposure to the operating staff and patient during MIS TLIF procedures using conventional fluoroscopy versus 3D fluoroscopy-based navigation combined with conventional fluoroscopy. Furthermore, recommendations regarding the appropriate use of the investigated intraoperative imaging techniques will be made to improve radiation protection and to reduce radiation exposure. TRIAL REGISTRATION Registration number of the German Clinical Trials Register: DRKS00004514 . Registration date: 11 August 2012.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion.

OBJECT Minimally invasive transforaminal lumbar interbody fusion (TLIF) is an increasingly popular procedure. The technique involves use of fluoroscopy to assist with pedicle screw (PS) placement. The potential exists for both the surgeon and the patient to become exposed to significant amounts of radiation. The authors undertook this study to quantify the radiation dose to the surgeon and pati...

متن کامل

Significant reduction of fluoroscopy repetition with lumbar localization system in minimally invasive spine surgery

The conventional location methods for minimally invasive spinal surgery (MISS) were mainly based on repeated fluoroscopy in a trial-and-error manner preoperatively and intraoperatively. Localization system mainly consisted of preoperative applied radiopaque frame and intraoperative guiding device, which has the potential to minimize fluoroscopy repetition in MISS. The study aimed to evaluate th...

متن کامل

[Assessment of the surgeon radiation exposure during a minimally invasive TLIF: Comparison between fluoroscopy and O-arm system].

INTRODUCTION Transforaminal lumbar interbody fusion with a minimally invasive approach (MIS TLIF) has become a very popular technique in the treatment of degenerative diseases of the lumbar spine, as it allows a decrease in muscle iatrogenic. However, iterative radiological controls inherent to this technique are responsible for a significant increase in exposure to ionizing radiation for the s...

متن کامل

Classification of Minimally Invasive Techniques for Transforaminal Lumbar Interbody Fusion

Minimally-invasive techniques for transforaminal lumbar interbody fusion have been shown to reduce intra-operative blood loss, muscle injury, post-operative pain and length-ofstay and expedite recovery compared to the open technique [1-11]. The main drawback has been increased intra-operative radiation exposure due to reliance on bi-planar fluoroscopy that is required to compensate for diminish...

متن کامل

Navigation-assisted fluoroscopy in minimally invasive direct lateral interbody fusion: a cadaveric study

BACKGROUND Minimally invasive surgery (MIS) is dependent on intraoperative fluoroscopic imaging for visualization, which significantly increases exposure to radiation. Navigation-assisted fluoroscopy (NAV) can potentially decrease radiation exposure and improve the operating room environment by reducing the need for real-time fluoroscopy. The direct lateral interbody fusion (DLIF) procedure is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015