Clinical Efficacy of Biodegradable Dental Implants of Tinidazole in Periodontitis.
نویسندگان
چکیده
Dental implants of tinidazole were formulated using poly (ε-caprolactone), a biodegradable polymer and evaluated. Clinical evaluation was carried out in ten patients with acute peridontitis. Various clinical parameters viz., gingival index, plaque score, attachment gain, reduction in pocket depth were evaluated after 10, 20, 30 and 40 days of treatment and compared with placebo as control. There was significant improvement in the healing of periodontal pockets treated with tinidazole implants as compared to the control sites. Estimation of tinidazole in gingival crevicular fluid (GCF) revealed that the drug levels above the minimum inhibitory concentration (5.9 μg/mg) for many of the periodontal pathogens was maintained throughout the period of study (40 days). This confirms the clinical efficacy of the dose and the duration of the study. It was found that biodegradable carrier was better accepted than the non-biodegradable carriers reported earlier.
منابع مشابه
Clinical evaluation of soft tissue surrounding prosthesis supported by implants
Clinical evaluation of soft tissue surrounding prosthesis supported by implants Dr. A. Fazel* - Dr. M. Rismanchian** *- Associate Professor of Prosthodontics Dept. - Faculty of Dentistry - Tehran University of Medical Sciences. **- Assistant Professor of Prosthodontics Dept. – Faculty of Dentistry - Isfahan University of Medical Sciences. Background and Aim: Nowadays, reconstruction and replace...
متن کاملComparison of the efficacy of Matrica and %0.2 Chlorhexidine mouthwashes on 3-6 mm pockets in patients with chronic periodontitis
Comparison of the efficacy of Matrica and %0.2 Chlorhexidine mouthwashes on 3-6 mm pockets in patients with chronic periodontitis Dr. M. Paknejad* - Dr. TS. Jafarzadeh** - Dr. AM. Shamloo*** *- Associate Professor of Periodontics Dept. - Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Dental Materials Dept. Faculty of Dentistry – Tehran University of Med...
متن کاملClinical Parameters and Crestal Bone Loss in Internal Versus External Hex Implants at One Year after Loading
Introduction: The survival of an implant system is affected by the choice of antirotational design, which can include an external or internal hex. Implant success also is affected by the maintenance of the crestal bone around implants. The aim of present study was to evaluate the crestal bone loss and clinical parameters related to bone loss in patients loaded with an external or internal hex 3...
متن کاملThe Role of Metallic Substrate of Hydroxyapatite Coated Dental Endodontic Implants in Clinical and Pathological Success
Hydroxyapatite coatings have been used on metallic substrates in a variety of applications, including modifying the surface of human implants, bone osseointegration and biological fixation. In this paper, the effects of various kinds of metallic substrate on clinical and pathological results of in vivo tests are presented. Four kinds of endodontic implants i.e, stainless steel, cobalt base all...
متن کاملThe Role of Metallic Substrate of Hydroxyapatite Coated Dental Endodontic Implants in Clinical and Pathological Success
Hydroxyapatite coatings have been used on metallic substrates in a variety of applications, including modifying the surface of human implants, bone osseointegration and biological fixation. In this paper, the effects of various kinds of metallic substrate on clinical and pathological results of in vivo tests are presented. Four kinds of endodontic implants i.e, stainless steel, cobalt base all...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Indian journal of physiology and pharmacology
دوره 43 1 شماره
صفحات -
تاریخ انتشار 1999