Open Flow Microperfusion as a Dermal Pharmacokinetic Approach to Evaluate Topical Bioequivalence
نویسندگان
چکیده
BACKGROUND The availability of generic topical dermatological drug products is constrained by the limited methods established to assess topical bioequivalence (BE). A novel cutaneous pharmacokinetic approach, dermal open-flow microperfusion (dOFM), can continuously assess the rate and extent to which a topical drug becomes available in the dermis, to compare in vivo dermal bioavailability (BA) and support BE evaluations for topical products. OBJECTIVE To evaluate whether dOFM is an accurate, sensitive, and reproducible in vivo method to characterize the intradermal BA of acyclovir from 5 % acyclovir creams, comparing a reference (R) product either to itself or to a different test (T) product. METHODS In a single-center clinical study, R or T products were applied to six randomized treatment sites on the skin of 20 healthy human subjects. Two dOFM probes were inserted in each treatment site to monitor the intradermal acyclovir concentration for 36 h. Comparative BA (of R vs. R and T vs. R) was evaluated based on conventional BE criteria for pharmacokinetic endpoints (area under the curve and maximum plasma concentration) where the 90 % confidence interval of the geometric mean ratio between the T and R falls within 0.80-1.25. RESULTS The positive control products (R vs. R) were accurately and reproducibly confirmed to be bioequivalent, while the negative control products (T vs. R) were sensitively discriminated not to be bioequivalent. CONCLUSIONS dOFM accurately, sensitively, and reproducibly characterized the dermal BA in a manner that can support BE evaluations for topical acyclovir 5 % creams in a study with n = 40 (20 subjects in this study).
منابع مشابه
Metabolite Parameters as an Appropriate Alternative Approach for Assessment of Bioequivalence of Two Verapamil Formulations
A bioequivalence study of two verapamil formulations (generic verapamil tablets and Isoptin® tablets) was performed by comparing pharmacokinetic parameters of the parent drug and its major metabolite, norverapamil following a single dose administration of 80 mg verapamil hydrochloride in 22 healthy volunteers according to a randomized, two-period, crossover-design study. Moreover, the feasibili...
متن کاملMetabolite Parameters as an Appropriate Alternative Approach for Assessment of Bioequivalence of Two Verapamil Formulations
A bioequivalence study of two verapamil formulations (generic verapamil tablets and Isoptin® tablets) was performed by comparing pharmacokinetic parameters of the parent drug and its major metabolite, norverapamil following a single dose administration of 80 mg verapamil hydrochloride in 22 healthy volunteers according to a randomized, two-period, crossover-design study. Moreover, the feasibili...
متن کاملبیواکی وین: نرم افزاری برای مطالعات هم ارزی زیستی
Abstract Introduction: Bioequivalence studies are the most important way of evaluating the quality and efficacy of pharmaceutical formulations. In a bioequivalence study, the rate and extent of drug absorption into the general circulation is measured and the pharmacokinetic parameters should be calculated and statistically evaluated for the reference and test products. Pharmacokinetic paramete...
متن کاملRapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies
A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...
متن کاملRapid High Performance Liquid Chromatographic Method for Determination of Clarithromycin in Human Plasma Using Amperometric Detection: Application in Pharmacokinetic and Bioequivalence Studies
A rapid, sensitive and reproducible HPLC method using amperometric detector was developed and validated for the analysis of clarithromycin in human plasma. The separation was achieved on a monolithic silica column (MZ- C8 125×4.0 mm) using acetonitrile- methanol-potassium dihydrogen phosphate buffer (40:6:54,v/v), with pH of 7.5, as the mobile phase at a flow rate of 1.5 mL/min. The assay enabl...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 56 شماره
صفحات -
تاریخ انتشار 2017