Treatment of intracranial aneurysms using detachable coils; initial results at a university hospital in Pakistan.
نویسندگان
چکیده
OBJECTIVE To evaluate the technical success, safety and outcome of endovascular coiling procedure in intracranial aneurysms. METHODS From April 2003 to April 2009, 43 patients (23 males and 20 females), age range 11 to 70 years, mean age 46.67 +/- 11.57 years were treated for intracranial aneurysms by detachable coil deployment at Radiology Department of Aga Khan University Hospital. Aneurysm rupture with subarachnoid haemorrhage was the cause of presentation in 39 patients while 4 patients were diagnosed with un-ruptured aneurysms. At time of presentation, grading of subarachnoid haemorrhage was done according to Hunt and Hess grading system. Eleven patients presented with Grade I haemorrhage, other 11 presented with grade II haemorrhage, 8 patients had grade III haemorrhage and 9 patients had grade IV haemorrhage. Preliminary diagnostic workup was performed by cross sectional imaging, CT angiography or digital substraction angiography. Coiling procedures were performed under general anaesthesia through femoral artery approach. Detachable platinum coils were densely packed in all aneurysms by endovascular technique. Patient files and radiology reports were retrospectively reviewed. Technical success and safety of the procedure were analyzed. Modified Rankin Score was used to determine clinical outcome. Score 0-2 represented good outcome, score 3-5: dependency (Can not attend own bodily needs and carry out daily activities without assistance) and score 6: death. RESULTS Aneurysm size ranged from 3mm - 22mm (mean size 8 mm +/- 4). 74.4% aneurysms had narrow necks while 25.6% aneurysms were wide necked. Most common aneurysm site was anterior communicating artery. Technical success rate for endovascular intracranial aneurysm coiling was 95.3% (n = 41). Major complication rate was 11.6 % (n = 5). Mortality rate was 2.3% (n = 1). 78% patients showed good clinical outcome after coiling including 4 patients with un ruptured aneurysms (n = 32). CONCLUSION Results of endovascular aneurysm coiling at our center showed high technical success rate (95.3%) and good short term clinical outcome in 78% patients.
منابع مشابه
Endovascular treatment of intracranial aneurysms with matrix detachable coils: immediate posttreatment results from a prospective multicenter registry.
BACKGROUND AND PURPOSE Endovascular treatment of intracranial aneurysms by using detachable coils has become an accepted alternative to surgery. To reduce the rate of aneurysm recanalization after treatment, biologically active polyglycolic/polylactic acid-covered platinum coils have been proposed. A prospective and multicenter registry was conducted in France to evaluate the safety and short-t...
متن کاملAneurysm retreatment after Guglielmi detachable coil and nondetachable coil embolization: report of nine cases and review of the literature.
OBJECTIVE Guglielmi detachable coil embolization of cerebral aneurysms is becoming increasingly used to manage certain intracranial lesions based on aneurysm geometry, patient condition, and patient and surgeon preferences. Aneurysm recurrences or incomplete initial treatments are not uncommon, making repeat treatment necessary using either surgical or endovascular techniques. METHODS Between...
متن کاملEndovascular Management of Wide-Necked Aneurysms
Endovascular management of intracranial aneurysms using detachable platinum coils (Guglielmi detachable coils, Target Therapeutics, Fremont, CA) was introduced in 1990 by Guido Guglielmi, an Italian neurosurgeon. Working in collaboration with Vinuela and others at the University of California at Los Angeles, along with Target Therapeutics, endovascular obliteration of aneurysms became a common ...
متن کاملEndovascular occlusion of intracranial aneurysms with electrically detachable coils: correlation of aneurysm neck size and treatment results.
PURPOSE To devise a method to measure aneurysm neck size on angiographic films, and to correlate the sizes obtained with the extent of endovascular aneurysm occlusion, performed with electrically detachable coils. METHODS The angiograms of 79 intracranial aneurysms treated by endovascular occlusion using electrically detachable coils were retrospectively analyzed. A method using the average r...
متن کاملMatrix detachable coils for the endovascular treatment of intracranial aneurysms: analysis of early angiographic and clinical outcomes.
BACKGROUND AND PURPOSE Endovascular coil embolization has become an accepted alternative for the treatment of intracranial aneurysms. The purpose of this study was to evaluate the clinical safety and the angiographic stability of aneurysm occlusion with a new class of biologically active platinum coils after a 6-month period. METHODS Twenty-five patients with 25 intracranial aneurysms were tr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- JPMA. The Journal of the Pakistan Medical Association
دوره 60 8 شماره
صفحات -
تاریخ انتشار 2010