An indicator-displacement assay for naked-eye detection and quantification of histidine in human urine.

نویسندگان

  • Shao-Kai Sun
  • Kai-Xiong Tu
  • Xiu-Ping Yan
چکیده

A simple and efficient colorimetric method for the naked-eye detection and quantification of histidine in biological fluids was developed based on an indicator-displacement assay (IDA) and the Ni(2+)-histidine affinity pair. In this IDA approach, a commercially available dye, murexide, was used as the indicator and the selective detection of histidine was achieved based on the competition between indicator and histidine for the binding with Ni(2+). The competition of histidine with murexide for Ni(2+) resulted in an obvious color change of the solution from yellow to purple, and the permitted naked-eye detection of trace histidine. The developed bioassay allows the rapid, sensitive and selective detection of histidine in urine samples, and does not need complicated sample pretreatment. The detection limit was 0.4 μM with a linear range from 2 to 30 μM. The relative standard deviation for 11 replicate detections of 8 μM histidine was 2.0%. The developed sensor was successfully applied to the determination of histidine in human urine samples with recoveries from 97 to 105%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Sensitivity and Specificity of Urine Survivin As A New Molecular Marker in Diagnosis of Bladder Tumors

Bladder cancer is one of the most common forms of cancers in the world. The current gold standards for itsdiagnosis are cystoscopy and urine cytology. Cystoscopy, a naked eye assessment of the bladder, is invasive, uncomfortable and costly with a great deal of personal variability in its results; while urine cytology has high specificity but low sensitivity, particularly for low-grade les...

متن کامل

Pyridinium-based symmetrical diamides as chemosensors in visual sensing of citrate through indicator displacement assay (IDA) and gel formation.

The design and synthesis of pyridinium-based symmetrical diamides 1 and 2 along with their anion binding studies through 'indicator-diplacement assay' are reported. Both the chemosensors effectively respond in in CH(3)CN-H(2)O (4 : 1 v/v) at pH = 6.3 for the selective naked-eye detection of citrate. Additionally, chemosensor 2 (c = 6.29 × 10(-3) M) forms a stable gel only with citrate in CH(3)C...

متن کامل

Naphthalene-based Azo-azomethine Chemosensor: Naked Eye Detection of Fluoride in Semi-aqueous Media

A new azo-azomethine chemosensor containing active phenolic sites, H2L, has been designed and synthesized for rapid detection of inorganic fluoride over the other anions, such as Clˉ, Brˉ, Iˉ, AcOˉ, H2PO4ˉ, NO3ˉ, N3ˉ in DMSO/water (90/10) media. The 1H NMR titration revealed that the colorimetric response was considered to be the direct consequence of hydrogen-bond formation between phenolic gr...

متن کامل

ارزیابی روش‌های الکتروایمونواسی و 100Clinitek- برای تشخیص میکروآلبومینوری

Evaluation of Electroimmunoassay and Clinitek-100 for Detection of Microalbuminuria B.A. Jalali Khanabadi PhD , H. Mozaffari Khosravi PhD Received: 12/10/05 Sent for Revision: 04/03/06 Received Revised Manuscript: 20/01/07 Accepted: 25/01/07 Background and Objective: Detection of microalbuminuria is an important laboratory test for evaluation of diabetic complications. A reliable me...

متن کامل

Indicator displacement assays that detect bilayer membranes enriched in phosphatidylserine

Three indicator displacement assays are described for the detection of phosphatidylserine in a bilayer membrane. A series of Zn-dipicolylamine coordination compounds are used to bind selectively to the phosphatidylserine and act as a colorimetric chemosensing ensemble when combined with the UV-Vis indictor pyrocatechol violet. A similar displacement assay uses a coumarin methylsulfonate derivat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Analyst

دوره 137 9  شماره 

صفحات  -

تاریخ انتشار 2012