Image Enhancement Using Calibrated Lens Simulations

نویسندگان

  • Yichang Shih
  • Brian Guenter
  • Neel Joshi
چکیده

All lenses have optical aberrations which reduce image sharpness. These aberrations can be reduced by deconvolving an image using the lens point spread function (PSF). However, fully measuring a PSF is laborious and prohibitive. Alternatively, one can simulate the PSF if the lens model is known. However, due to manufacturing tolerances lenses differ subtly from their models, so often a simulated PSF is a poor match to measured data. We present an algorithm that uses a PSF measurement at a single depth to calibrate the nominal lens model to the measured PSF. The calibrated model can then be used to compute the PSF for any desired setting of lens parameters for any scene depth, without additional measurements or calibration. The calibrated model gives deconvolution results comparable to measurement but is much more compact and require hundreds of times fewer calibration images.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The impact of lens galaxy environments on the image separation distribution

We study the impact of lens galaxy environments on the image separation distribution of lensed quasars. We account for both environmental convergence and shear, using a joint distribution derived from galaxy formation models calibrated by galaxy–galaxy lensing data and number counts of massive elliptical galaxies. We find that the external field enhances lensing probabilities, particularly at l...

متن کامل

Assessing the image quality and eye lens dose reduction using bismuth shielding in computed tomography of brain

Background: Epidemiological studies show that computed tomography (CT) is one of the main sources of ionizing radiations. Shielding of radiosensitive organs is one of the dose reduction methods. This study aimed to assess the eye lens dose reduction and image quality resulting from the use of radio-protective bismuth shield in brain CT imaging. Methods: Bismut...

متن کامل

A Simple Calibration Procedure for Fish-Eye (High-Distortion) Lens Camera

This paper presents a new algorithm for the geometric camera calibration of a fish-eye lens (a high distortion lens) mounted on a CCD TV camera. The algorithm determines a mapping between points in the world coordinate system and their corresponding point locations in the image plane. The parameters to be calibrated are effective focal length, one-pixel width on the image plane, image distortio...

متن کامل

A Semi-Automatic Image-Based Close Range 3D Modeling Pipeline Using a Multi-Camera Configuration

The generation of photo-realistic 3D models is an important task for digital recording of cultural heritage objects. This study proposes an image-based 3D modeling pipeline which takes advantage of a multi-camera configuration and multi-image matching technique that does not require any markers on or around the object. Multiple digital single lens reflex (DSLR) cameras are adopted and fixed wit...

متن کامل

A method of reactive zoom control from uncertainty in tracking

The tuning of a constant velocity Kalman filter, used for tracking by a camera fitted with a variable focal-length lens, is shown to be preserved under a scale change in process noise if accompanied by an inverse scaling in the focal length, provided the image measurement error is of fixed size in image coordinates. Based on this observation, a practical method of zoom control has been built by...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012