Long-term clinical and echocardiographic follow-up of the Freestyle stentless aortic bioprosthesis.

نویسندگان

  • Siamak Mohammadi
  • Vincent Tchana-Sato
  • Dimitri Kalavrouziotis
  • Pierre Voisine
  • Daniel Doyle
  • Richard Baillot
  • Sandro Sponga
  • Jacques Metras
  • Jean Perron
  • François Dagenais
چکیده

BACKGROUND Stentless aortic bioprostheses were designed to provide enhanced hemodynamic performance and potentially greater longevity. The present report describes the outcomes of patients with the Freestyle stentless bioprosthesis followed for ≤18 years. METHODS AND RESULTS Between 1993 and 2011, 430 patients underwent primary aortic valve replacement with a Freestyle bioprosthesis in the subcoronary position. Mean age was 68.2 ± 8.2 years. All of the clinical and echocardiographic data were collected prospectively. Mean overall follow-up was 9.1 ± 4.4 years and was complete in all of the patients. In-hospital mortality was 3.5% (n=15). Overall, 10- and 15-year survival were 60.7% and 35.0%, respectively. Fifty-one patients required reoperation during follow-up, including 27 for structural valve deterioration (SVD). Overall, freedom from reoperation was 91.0% and 75.0% at 10 and 15 years, whereas freedom from reoperation for SVD was 95.9% and 82.3%, respectively. At 10 and 15 years, freedom from reoperation for SVD was 94.0% and 62.6% for patients <60 years of age and 96.3% and 88.4% for patients ≥60 years of age (P=0.002). The median time to explant for SVD was 10.7 years. SVD presented mostly as acute, severe aortic insufficiency attributed to leaflet tear (77.8%). The independent risk factors for reoperation for SVD were age <60 years (P=0.001) and dyslipidemia (P=0.02). CONCLUSIONS Aortic valve replacement with the Freestyle bioprosthesis in a subcoronary position provides good long-term clinical and echocardiographic outcomes for patients >60 years of age. Severe aortic insufficiency with leaflet tear is the major mode of SVD leading to reoperation in these patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Long-term clinical outcomes 15 years after aortic valve replacement with the Freestyle stentless aortic bioprosthesis.

BACKGROUND The Freestyle stentless aortic root bioprosthesis has excellent hemodynamics and durability through 10 years. The purpose of this report is to present clinical outcomes in a large multicenter cohort through 15 years. METHODS The multicenter evaluation of the Freestyle valve began in 1992 at 21 centers in North America and Europe. In 1997, a long-term study continued, including 725 ...

متن کامل

Long-term clinical and echocardiographic follow-up of the freestyle stentless aortic bioprosthesis: the Tel Aviv Medical Center experience.

BACKGROUND Stentless aortic bioprostheses were designed to provide improved hemodynamic performance and potentially better survival. OBJECTIVES To report the outcomes of patients after aortic valve replacement with the Freestyle stentless bioprosthesis at the Tel Aviv Medical Center followed for < or = 15 years. METHODS AND RESULTS Between 1997 and 2011, 268 patients underwent primary aorti...

متن کامل

Structural deterioration of the Freestyle aortic valve: mode of presentation and mechanisms.

BACKGROUND Structural valve deterioration is the major cause of bioprosthetic valve failure. Because of the unique design features and anti-calcification treatment of the Freestyle (Medtronic Inc, Minneapolis, Minn) stentless bioprosthesis, development of structural valve deterioration may differ in comparison with other bioprosthetic valves. This study evaluates the mechanisms and clinical pre...

متن کامل

Freestyle stentless bioprosthesis for aortic valve therapy: 17-year clinical results.

BACKGROUND Aortic valve replacement with stentless bioprostheses has been shown to produce lower aortic gradients than stented bioprostheses, thus facilitating left ventricular mass regression and preventing heart failure. We sought to determine the long-term results of stentless biological aortic valve replacement over a 17-year follow-up. METHODS Between 1996 and 2012, 2551 patients underwe...

متن کامل

Kangaroo versus freestyle stentless bioprostheses in a juvenile sheep model: hemodynamic performance and calcification behavior.

BACKGROUND Glutaraldehyde-preserved bioprosthetic heart valve substitutes have limited performance and longevity due to tissue degeneration and calcification. The Freestyle valve (Medtronic Heart Valves, Inc, Minneapolis, MN) combines zero fixation pressure and proportional, variant-amino oleic acid (AOA) as antidegeneration and antimineralization measures. The aim of this study was to compare ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 126 11 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2012