Clinical profile and incidence of ventricular arrhythmia in patients undergoing defibrillator generator replacement in Spain.
نویسندگان
چکیده
INTRODUCTION AND OBJECTIVES Implantable cardioverter-defibrillators reduce mortality in some patients with heart disease. Battery replacement is a frequent occurrence in clinical practice and is required in up to 30% of implants. The benefit/risk ratio of defibrillators varies over time and should be reevaluated at the time of replacement. The aim of this study was to determine the clinical characteristics and incidence of defibrillator therapies in patients who underwent generator replacement. METHODS This multicenter retrospective study involved patients from the UMBRELLA national registry who underwent replacement due to defibrillator battery depletion. The incidence of ventricular arrhythmias was determined via remote monitoring. Risk factors for sustained ventricular arrhythmia after replacement were analyzed. RESULTS A total of 354 patients were included (mean age [standard deviation], 61.8 [14.5] years; men, 80%; secondary prevention, 42%; ventricular arrhythmias in the explanted generator, 62%). After a 25-month follow-up, 70 patients (20%) received appropriate therapies and 8 (2.3%) received inappropriate discharges. Male sex, structural heart disease, heart failure, and the absence of resynchronization were independent predictors of ventricular arrhythmia occurrence. CONCLUSIONS One-fifth of patients had appropriate defibrillator therapies in the first 2 years after generator replacement. Determination of the factors associated with arrhythmia occurrence after replacement may be useful to optimize implantable cardioverter-defibrillator treatment.
منابع مشابه
Restratification at Time of Implantable Cardioverter Defibrillator Replacement Reestratificación en el momento del recambio del desfibrilador automático implantable
Based on the results of several large, randomized, clinical trials, implantable cardioverter defibrillators (ICDs) have become a ‘‘gold standard’’ therapy in prevention of sudden cardiac death. Under current guidelines, ICDs are implanted in patients who survived cardiac arrest or hemodynamically unstable ventricular tachycardia, as well as in primary prevention, mainly for those with ischemic ...
متن کاملRestratification at time of implantable cardioverter defibrillator replacement.
Based on the results of several large, randomized, clinical trials, implantable cardioverter defibrillators (ICDs) have become a ‘‘gold standard’’ therapy in prevention of sudden cardiac death. Under current guidelines, ICDs are implanted in patients who survived cardiac arrest or hemodynamically unstable ventricular tachycardia, as well as in primary prevention, mainly for those with ischemic ...
متن کاملIncidence of lead system malfunction detected during implantable defibrillator generator replacement.
Implantable cardioverter-defibrillator (ICD) generator replacement due to a depleted battery is a frequently performed procedure. The frequency with which sensing and defibrillation system failures are identified during device replacement procedures has not been previously described. Therefore, the purpose of this study was to prospectively determine the frequency of lead system malfunction det...
متن کاملPrevalence of bacterial colonization of generator pockets in implantable cardioverter defibrillator patients without signs of infection undergoing generator replacement or lead revision.
AIMS This study was designed to evaluate the prevalence of bacterial colonization of generator pockets in implantable cardioverter defibrillator (ICD) patients without signs of infection and to analyse the impact of bacterial colonization on the incidence of device infection during follow-up. METHODS AND RESULTS In 122 ICD patients undergoing generator replacement or surgical lead revision be...
متن کاملDelayed AICD therapy and cardiac arrest resulting from undersensing of ventricular fibrillation in a subject with hypertrophic cardiomyopathy-A case report.
Defibrillation testing is no longer routinely performed after automatic implantable cardioverter-defibrillator (AICD) implantation. However, certain subjects undergoing AICD implantation may be at higher risk of undersensing of ventricular arrhythmias resulting in potentially fatal outcomes. We present the case of a 30-year-old woman with hypertrophic cardiomyopathy (HCM; 'asymmetric septal hyp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Revista espanola de cardiologia
دوره 67 12 شماره
صفحات -
تاریخ انتشار 2014