A simplified, single-lead unipolar transvenous cardioversion-defibrillation system.
نویسندگان
چکیده
BACKGROUND Transvenous implantable cardioverter-defibrillators provide significant advantages in the treatment of patients with life-threatening ventricular arrhythmias. However, present technology requires considerable electrophysiology expertise, multiple incisions, and long operative times for successful implementation. METHODS AND RESULTS In this study, we present a prototype of a new, easy-to-insert unipolar transvenous defibrillation system that has the reliability of epicardial defibrillation but the ease of pacemaker insertion. This system incorporates a single anodal right ventricular defibrillation electrode using a 65% tilt biphasic pulse delivered to a 108-cm2 surface area pulse generator titanium alloy shell as an active cathode placed in a left infraclavicular pocket. Testing of this system was performed before implantation of a standard nonthoracotomy-transvenous defibrillation system in 40 consecutive patients with a history of ventricular tachycardia or fibrillation. The simplified unipolar single-lead system resulted in a defibrillation threshold of 9.3 +/- 6.0 J with 37 of 40 patients (93%) having a defibrillation threshold of less than 20 J. Moreover, the unipolar defibrillation system was efficiently used requiring only 3.4 +/- 0.8 ventricular fibrillation inductions to measure the defibrillation threshold and 100 +/- 28 minutes to implement. CONCLUSIONS This new unipolar transvenous defibrillation system is as simple to insert as a pacemaker, requires few ventricular fibrillation inductions, demands less technical expertise, and provides defibrillation at energy levels comparable to that reported with epicardial lead systems. It should substantially reduce the morbidity, time, and cost of defibrillator implantation.
منابع مشابه
A Prospective, Randomized Study
Background Recent development of a prototype singlelead unipolar transvenous defibrillator offers the possibility of device implantation with the ease of a permanent pacemaker. Lowering defibrillation energy requirements would allow for a further reduction in defibrillator generator size and enhance the feasibility of pacemaker-like placement. However, if achieving a lower defibrillation energy...
متن کاملProspective, randomized comparison in humans of a unipolar defibrillation system with that using an additional superior vena cava electrode.
BACKGROUND A unipolar defibrillation system using a single right ventricular (RV) electrode and the active shell or "CAN" of the implantable cardioverter-defibrillator itself situated in a left infraclavicular pocket has been shown to be as efficient in defibrillation as an epicardial lead system. The purpose of this study was to determine whether defibrillation efficacy can be improved further...
متن کاملSuperior Vena Cava Electrode
Background A unipolar defibrillation system using a single right ventricular (RV) electrode and the active shell or "CAN" of the implantable cardioverter-defibrillator itself situated in a left infraclavicular pocket has been shown to be as efficient in defibrillation as an epicardial lead system. The purpose of this study was to determine whether defibrillation efficacy can be improved further...
متن کاملComparison of single- and dual-coil active pectoral defibrillation lead systems.
OBJECTIVES The purpose of this study was to compare defibrillation thresholds with lead systems consisting of an active left pectoral electrode and either single or dual transvenous coils. BACKGROUND Lead systems that include an active pectoral pulse generator reduce defibrillation thresholds and permit transvenous defibrillation in nearly all patients. A further improvement in defibrillation...
متن کاملInternal cardioversion of atrial fibrillation in sheep.
BACKGROUND The cardioversion efficacy of multiple defibrillation waveforms and electrode systems was compared in a sheep model of atrial fibrillation. METHODS AND RESULTS Sustained atrial fibrillation could be induced with rapid atrial pacing in 23 (55%) of the animals. This study was performed in four parts. Six sheep with sustained atrial fibrillation were used for data analysis for each pa...