A simple method for the determination of lipid composition of human bile.
نویسندگان
چکیده
The Entero-Test, a device for easy sampling of gastrointestinal contents, including bile, has been used for determination of biliary lipid composition. The device consists of a weighted gelatin capsule containing 140 cm of a highly absorbent nylon line. The capsule is swallowed while one end of the string is taped to the face. After 3.5 h, when the line has reached the duodenum, gallbladder contraction is stimulated by intramuscular administration of ceruletide. The line is pulled out, and the last 15 cm are eluted four times in methanol. Total bile acids (by 3 alpha-hydroxysteroid-dehydrogenase assay), individual bile acids (by high performance liquid chromatography), phospholipids (by assay of lipid-soluble phosphorus), and cholesterol (by gas-liquid chromatography) are determined in the eluate. Tests in vitro demonstrated no preferential binding and a good recovery of biliary lipids from the thread. Similar values of biliary cholesterol saturation were obtained by means of duodenal intubation and of the Entero-Test in a series of 12 subjects (r = 0.952). In 5 subjects, individual bile acids were also measured and were found to be similar with both techniques (r = 0.948). When the test was repeated over 3 days in a series of 7 subjects, biliary cholesterol saturation was found to be remarkably reproducible (CV = 7.6%). Thus, the Entero-Test is a convenient technique for the determination of biliary lipid composition, which can be particularly useful in longitudinal studies.
منابع مشابه
Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملUse of a simple enzymatic assay for cholesterol analysis in human bile.
An enzymatic technique for cholesterol analysis in serum was applied to human bile. The analytical yield was very satisfactory in experiments in which known amounts of cholesterol were added to untreated, as well as Millipore-filtered, samples of human bile. The analytical results of the enzymatic test agreed closely with those of a method utilizing the Liebermann-Burchard reaction. The enzymat...
متن کاملFatty Acid Composition of Human Follicular Fluid Phospholipids and Fertilization Rate in Assisted Reproductive Techniques
Background: Fatty acids are known to be critically important in multiple biological functions. Phospholipid fatty acids of follicular fluid, an important microenvironment for the development of oocytes, may contribute to the women’s fertility and the efficacy of assisted reproduction techniques. The aim of this study was to investigate the effect of fatty acid composition of follicular fluid ph...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of lipid research
دوره 32 2 شماره
صفحات -
تاریخ انتشار 1991