The Swan-Ganz catheters: past, present, and future. A viewpoint.

نویسنده

  • Kanu Chatterjee
چکیده

The Swan-Ganz balloon flotation catheter was introduced in 1970. It can be placed at the bedside within a few minutes even in critically ill patients. Although placement of these catheters is not difficult, some training and experience are required to avoid complications and for proper interpretation of the hemodynamic data that can be obtained by pulmonary artery catheterization. Because of the many advantages of balloon flotation catheters compared with conventional catheters, they have been used without a proper indication and frequently overused in critical care units, resulting in many complications, including mortality. The prospective randomized trials have reported that in the majority of clinical circumstances, the routine use of balloon flotation catheters is not indicated. These results are not surprising because balloon flotation catheters are diagnostic and not therapeutic tools. That we have learned a great deal about hemodynamics in critically ill patients with the use of balloon flotation catheters should not be ignored or forgotten. Furthermore, our clinical knowledge of hemodynamics has been made possible because of extensive experience gained from directly determined hemodynamics with the use of balloon flotation catheters. It should also be realized that despite the introduction and refinement of newer noninvasive imaging modalities, a number of clinical circumstances exist in which determination of hemodynamics with the use of a balloon flotation catheter is necessary and should be considered, but only by experienced physicians. With the proper use of Swan-Ganz catheters, our knowledge of hemodynamics has been enhanced considerably. Its abuse, particularly by relatively inexperienced operators, has resulted in serious complications, including death. Prospective randomized clinical trials have demonstrated that the routine use of Swan-Ganz catheters does not provide any benefit. However, use of the Swan-Ganz catheter is still indicated in many situations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

[The Swan-Ganz catheter--past, present and future].

The Swan-Ganz balloon flotation catheter was introduced in 1970. It can be placed at the bedside within a few minutes even in critically ill patients. Although placement of these catheters is not difficult, some training and experience are required to avoid complications and for proper interpretation of the hemodynamic data that can be obtained by pulmonary artery catheterization. Because of th...

متن کامل

Latex anaphylaxis caused by a Swan-Ganz catheter.

A 78-year-old woman visited the division of cardiovascular disease in our hospital. She underwent a cardiac catheter examination, and a Swan-Ganz catheter was inserted. Several minutes later, she developed anaphylactic shock. She had no past history of latex allergy, but did have a banana allergy. Skin prick tests showed a positive reaction to an extract of latex gloves and an extract of the ba...

متن کامل

Hepatic vein obstruction due to Swan-Ganz catheter placement.

Complications from Swan-Ganz catheters during insertion, long-term placement, or removal have been known since its development. I describe the unusual presentation of a pacing Swan-Ganz catheter mispositioned into the hepatic vein producing vascular obstruction, yet with adequate cardiac pacing.

متن کامل

Cardiac output monitoring by echocardiography: should we pass on Swan-Ganz catheters?

Transesophageal echocardiography offers a noninvasive technique for the continuous monitoring of cardiac performance. The combination of 2-dimensional echocardiography and Doppler velocitometry provide assessment of cardiac anatomy, valve function and, ventricular loading conditions. Although transesophageal echocardiography has become accepted for perioperative monitoring, it is typically used...

متن کامل

Swan-Ganz catheter-induced pulmonary artery pseudoaneurysm formation: three case reports and a review of the literature.

The use of Swan-Ganz catheters has increased tremendously since they were first introduced in 1970. Their ability to give vital hemodynamic measurements in critically ill patients makes their use invaluable when providing quality medical care. The formation of pulmonary artery (PA) pseudoaneurysm from a Swan-Ganz catheter-induced perforation of the PA is a rare but potentially fatal complicatio...

متن کامل