The behaviour of the WFC3 UVIS and IR Analog-to-Digital Converters

نویسنده

  • M. Robberto
چکیده

Using UVIS and IR data from the 2004 thermal vacuum tests, we have searched for anomalous behavior in the WFC3’s analog-to-digital converters (ADCs). We find that the ADCs of the CCD channel operate nominally, except for the less significant bits which favor 1’s over 0’s by up to 5%, depending on the ADC and on the input voltage. The IR channel, clocked at double speed, also shows departures in the least significant bits at ~1% level. These departures from ideal behaviour are statistically significant. We discuss the relevance of these anomalies for the scientific quality of the WFC3 data, simulating images affected by biased ADCs at 1% and 2% level. Whereas the occasional anomalous bits corresponding to signal levels around the cosmic ray filtering threshold may represent a source of salt-pepper noise hard to eliminate, for both the UVIS and the IR channels the added readnoise is negligible and does not affect the ultimate sensitivity of the instrument. The advantages of clocking the CCD detectors at double speed to reduce the detector cross talk largely supersede the disadvantages of the measured extra ADC noise.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improving adaptive resolution of analog to digital converters using least squares mean method

This paper presents an adaptive digital resolution improvement method for extrapolating and recursive analog-to-digital converters (ADCs). The presented adaptively enhanced ADC (AE-ADC) digitally estimates the digital equivalent of the input signal by utilizing an adaptive digital filter (ADF). The least mean squares (LMS) algorithm also determines the coefficients of the ADF block. In this sch...

متن کامل

Analysis of Integral Nonlinearity in Radix-4 Pipelined Analog-to-Digital Converters

In this paper an analytic approach to estimate the nonlinearity of radix-4 pipelined analog-to-digital converters due to the circuit non-idealities is presented. Output voltage of each stage is modeled as sum of the ideal output voltage and non-ideal output voltage (error voltage), in which non-ideal output voltage is created by capacitor mismatch, comparator offset, input offset, and finite ga...

متن کامل

WFC3/UVIS Detectors: On-orbit Performance

WFC3 is a fourth-generation instrument installed on HST in May 2009. Designed as a panchromatic camera, it features both a UVIS and an IR channel, selectable via a channel select mechanism (CSM), allowing sequential imaging. Both detectors are performing well on-orbit and are now in standard science operations. This poster presents some of the UVIS detector highlights as well as remaining issue...

متن کامل

Wfc3 Uvis and Ir Channel Alignment Properties

____________________________________________________________________________ Abstract The purpose of this ISR is to study the sensitivity of the WFC3 UVIS and IR channels to the focus and tilt of their correctors in preparation for the optical alignment of the instrument. This study is done by using the same IDL routines which will be used during the instrument optical alignment at Ball and at ...

متن کامل

WFC3 SMOV Proposal 11549: Image Stability

I review the image stability tests performed during the Servicing Mission Observatory Verification (SMOV) campaign for the Wide Field Camera 3 (WFC3). These tests were performed using repeated observations of globular clusters with the telescope oriented at hot and cold thermal attitudes. As expected from ground tests in 2007, the WFC3 image stability is slightly worse than specifications. The ...