Differences in frequency of finger tremor in otherwise asymptomatic mercury workers.

نویسندگان

  • L J Chapman
  • S L Sauter
  • R A Henning
  • V N Dodson
  • W G Reddan
  • C G Matthews
چکیده

Tremor was measured from the index finger during low force, position holding in 18 control subjects and 18 battery workers with low level exposure to mercury. All workers were asymptomatic on clinical neurological examination. No differences were found in average tremor amplitudes between the groups, but statistically significant abnormalities in tremor frequency distribution existed. Tremor power spectra in the group of mercury workers were shifted toward the higher frequencies and compressed into narrow frequency peaks. These results suggest that measurements of finger tremor that evaluate the frequency distribution can produce a higher diagnostic yield than traditional visual clinical judgement. The findings also confirm other reports that currently permitted exposures to mercury are associated with subtle but distinctive differences in tremor accompanying voluntary movement.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mercury exposures and symptoms in smelting workers of artisanal mercury mines in Wuchuan, Guizhou, China.

Mercury exposures to smelting workers of artisanal mercury mines in Wuchuan, Guizhou, China were evaluated by urine and hair mercury survey. The mean urinary mercury (U-Hg), hair total mercury (T-Hg), and hair methyl mercury (Me-Hg) for smelting workers was 1060 microg/g creatinine (microg/g Cr), 69.3 and 2.32 microg/g, respectively. The results were significantly higher than that of control gr...

متن کامل

The complete frequency spectrum of physiological tremor can be recreated by broadband mechanical or electrical drive.

Two frequency peaks of variable preponderance have been reported for human physiological finger tremor. The high-frequency peak (20-25 Hz, seen only in postural tremor) is generally attributed to mechanical resonance, whereas the lower frequency peak (8-12 Hz, seen in both postural and kinetic tremor) is usually attributed to synchronous central or reflexive neural drive. In this study, we dete...

متن کامل

Effects of occupational exposure to mercury vapour on the central nervous system.

Possible effects of mercury on the central nervous system (CNS) were examined in a group of chloralkali workers exposed to mercury (n = 89) and compared with a control group (n = 75), by registration of subjective symptoms, personality changes, forearm tremor, and performance on six computerised psychometric tests in the two groups. The groups were similar in age, education, verbal comprehensio...

متن کامل

A dominant role for mechanical resonance in physiological finger tremor revealed by selective minimization of voluntary drive and movement.

There is a debate in the literature about whether the low- and high-frequency peaks of physiological finger tremor are caused by resonance or central drive. One way to address this issue is to examine the consequences of eliminating, as far as possible, the resonant properties or the voluntary drive. To study the effect of minimizing resonance, finger tremor was recorded under isometric conditi...

متن کامل

The Complete Frequency Spectrum of Physiological Tremor Can Be Recreated by Broad-band Mechanical or Electrical Drive. Running Title: Physiological Tremor Can Be Recreated by Broad-band Drive Aix-marseille Université Et Cnrs

16 Two frequency peaks of variable preponderance have been reported for human physiological 17 finger tremor. The high frequency peak (20-25 Hz, seen only in postural tremor) is generally 18 attributed to mechanical resonance, whereas the lower frequency peak (8-12 Hz, seen both in 19 postural and kinetic tremor) is usually attributed to synchronous central or reflexive neural 20 drive. Here, w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of industrial medicine

دوره 47 12  شماره 

صفحات  -

تاریخ انتشار 1990