Automatic implantable cardioverter/defibrillator discharges and acute myocardial injury.

نویسندگان

  • B Avitall
  • S Port
  • R Gal
  • J McKinnie
  • P Tchou
  • M Jazayeri
  • P Troup
  • M Akhtar
چکیده

Multiple defibrillations by the automatic implantable cardioverter/defibrillator (AICD) have been reported to result in localized epicardial damage. No data exist, however, regarding whether this damage can be detected in the clinical setting or whether it interferes with the detection of true myocardial infarction. Forty-nine patients who received defibrillations by patch electrodes were studied prospectively. We attempted to document the presence of myocardial injury with the following three commonly used modalities for the detection of myocardial infarction: serial electrocardiographic changes, serial creatine phosphokinase (CPK) and CPK-MB release, and technetium 99m pyrophosphate scanning. Fifteen patients received defibrillations by AICD patches at the time of AICD generator replacement. Nine patients received defibrillations at the time of new AICD lead placement. The average total energy delivered was 85 +/- 29 J. None of these patients had detectable myocardial injury. Ten patients had defibrillations by the AICD patches at the time of bypass operation. One patient in this group developed acute myocardial infarction in the inferior wall after posterior descending coronary bypass operation, as detected by electrocardiogram, 99mTc pyrophosphate scanning, and CPK-MB analysis. Fifteen patients were evaluated for spontaneous AICD discharges. Thirteen had a maximum of five consecutive shocks, and cumulative energy delivered was not greater than 330 J. None of these patients had detectable injury. Two patients had CPK-MB release of 15.3% and 7.5%, respectively. One of these patients had a positive 99mTc pyrophosphate scan. These two patients received 12 and 17 rapid and consecutive AICD discharges, respectively, with cumulative delivered energy of 360 and 510 J, respectively.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE EFFECT OF NURSE-PEER-LED SUPPORT INTERVENTION ON QUALITY OF LIFE IN PATIENTS WITH AN IMPLANTABLE CARDIOVERTER-DEFIBRILLATOR: A RANDOMIZED CLINICAL TRIAL

Background & Aims: Nowadays, the quality of life and how coping and treatment of patients with an implantable cardiac defibrillator has led to concern and attempts to reduce or eliminate the problems of these patients in the people who provide health care services. This study aimed to determine the effect of nurse-peer-led support intervention on quality of life in patients with an implantable ...

متن کامل

Implantable cardioverter-defibrillator in a patient with dextrocardia situs inversus

Background: Dextrocardia is a congenital anomaly, which may have coexistent coronary artery disease (CAD), arrhythmias and conventional indications for device therapy. However, the implantation of transvenous leads can be technically challenging and the approach needs to be tailored to the patient's individual anatomy. Case presentation: A 54-year-old male with dextrocardia situs inversus and i...

متن کامل

[Prevalence and clinical course of patients in Spain with acute myocardial infarction and severely depressed ejection fraction who meet the criteria for automatic defibrillator implantation].

The Multicenter Automatic Defibrillator Implantation Trial (MADIT)-II has broadened the indications for cardioverter defibrillator implantation. We present a retrospective study designed to estimate the number of patients in Spain eligible for an implantable defibrillator according to the MADIT-II criteria. From January 1999 to October 2002, 758 consecutive patients were admitted to our center ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 81 5  شماره 

صفحات  -

تاریخ انتشار 1990