Comparative study of antibacterial and antifungal effects of rigid gas permeable contact lens disinfecting solutions.

نویسندگان

  • Tomislav Kuzman
  • Marija Barisić Kutija
  • Rajko Kordić
  • Smiljka Popović-Sui
  • Sonja Jandroković
  • Ivan Skegro
  • Rajko Pokupec
چکیده

The aim of this study was to compare antimicrobial efficacy of rigid contact lens disinfecting solutions. We tested five commercially available solutions: Unique pH (Alcon Laboratories), Boston Advance (Polymer Technology Corp.), Nitilens Conditioner GP (Avizor), Total Care (AMO), Boston Simplus (Bausch&Lomb). Their efficacy to disinfect saline solution experimentally contaminated with American Type Culture Collection (ATCC): Staphylococcus aureus (ATCC 25923), Escherichia coli (ATCC 25922), Pseudomonas aeruginosa (ATCC 27853), Candida albicans (ATCC 90028) and Staphylococcus epidermidis (isolated from our laboratory) was tested. All tested solutions reduced concentrations of bacteria and fungi below 1000 CFU/mL (Colony forming unit; reduction by 3 log and 1 log, respectively) after the 8 hours period. Overall, all contact lens care solutions showed good disinfecting activity against tested bacteria and fungi, with more variation in their antifungal than in antibacterial efficacy. Results of our study might be valuable when selecting appropriate solutions for non-compliant contact lens wearers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adaptation and growth of Serratia marcescens in contact lens disinfectant solutions containing chlorhexidine gluconate.

Serratia marcescens (11 of 12 strains) demonstrated an ability to grow in certain chlorhexidine-based disinfecting solutions recommended for rigid gas-permeable contact lenses. For a representative strain, cells that were grown in nutrient-rich medium, washed, and inoculated into disinfecting solution went into a nonrecoverable phase within 24 h. However, after 4 days, cells that had the abilit...

متن کامل

Anti-Acanthamoeba activity of contact lens solutions.

AIMS This study was undertaken to investigate the effects of contact lens disinfecting solutions on strains of Acanthamoeba from the United Kingdom and southern Africa and to compare the results with those of other researchers. No information was previously available for southern African isolates. METHODS 11 contact lens solutions were tested on cysts of 10 strains of Acanthamoeba. RESULTS ...

متن کامل

Rigid Gas Permeable Contact Lens as a Vision-Sparing Tool in Children After Traumatic Corneal Laceration.

PURPOSE To evaluate the clinical value of rigid gas permeable contact lenses in children after traumatic corneal scarring. METHODS This comparative study included 15 children (age range: 5.7 to 14 years; mean ± standard deviation = 9.4 ± 2.9 years) with corneal scars and best corrected visual acuity (BCVA) of worse than 20/20, history of penetrating ocular trauma, and/or cataract extraction. ...

متن کامل

Biocompatibility and cytotoxicity study of nanophotonic rigid gas permeable contact lens material

Since materials on nanoscale have different characteristics from materials on macro scale their biocompatibility should be precisely and specifically investigated. Fullerenes, the third carbon allotrope, are one of the most used nanomaterials. The least stable and the most common is fullerene C60. One of the main disadvantages of fullerene is its low solubility in water. In order to make it sol...

متن کامل

Contact lens rehabilitation following repaired corneal perforations

BACKGROUND Visual outcome following repair of post-traumatic corneal perforation may not be optimal due to presence of irregular keratometric astigmatism. We performed a study to evaluate and compare rigid gas permeable contact lens and spectacles in visual rehabilitation following perforating corneal injuries. METHOD Eyes that had undergone repair for corneal perforating injuries with or wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Collegium antropologicum

دوره 37 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2013