Measurement of coronary collateral flow and resistance in the presence of an open critical stenosis, and the response to intra-arterial thrombosis.
نویسندگان
چکیده
OBJECTIVE (1) Can one measure coronary collateral flow around an open critical stenosis? (2) Does intracoronary platelet thrombosis affect native coronary collateral vessels? METHODS We measured regional myocardial blood flow by the radioactive microsphere technique in seven anaesthetised dogs with an ultrasonic flowmeter on the circumflex branch of the left coronary artery (LCx). Measurements were made (a) in a control period, (b) after induction of a tight stenosis on the LCx, and (c) after additional arterial damage at the stenosis to induce intraluminal thrombosis. Collateral flow was calculated from LCx tissue flow(in ml/min/g tissue) minus LCx flowmeter flow which is in ml/min. Therefore, it was necessary to use scaling by reference back to the control measurements and conversion to ml/min/g tissue equivalent. RESULTS LCx stenosis induced collateral flow from the other coronary arteries into the LCx area of supply, which decreased (mean+/-S.E.) from 0.23+/-0.03 to 0.15+/-0.05 ml/min/g tissue with thrombosis. Collateral resistance correspondingly increased with thrombosis from 187.6+/-18. 2 to 1069+/-544 mmHg/ml/min/g (P<0.02). CONCLUSION Coronary collateral flow around an open stenosis can be measured by reference back to control conditions. The coronary collaterals vasoconstrict in the presence of thrombosis even though they are in the stream of blood coming from normal coronary arteries.
منابع مشابه
تاثیر انسداد شریان کاروتید داخلی (ICA) در میزان مرگ ومیر وعوارض بیماران تحت عمل جراحی گرافت شریان کرونری(CABG)
Background and Aim: Stroke is an important cause of morbidity and mortality in patients undergoing coronary artery bypass (CABG) surgery. There are various mechanisms that can cause prioperative strokes in patients undergoing CABG other than Carotid Artery disease. The goal of this study is to evaluate whether the presence of stenosis internal carotid artery (ICA) influences prioperative stroke...
متن کاملAn implicit finite difference scheme for analyzing the effect of body acceleration on pulsatile blood flow through a stenosed artery
With an aim to investigate the effect of externally imposed body acceleration on two dimensional,pulsatile blood flow through a stenosed artery is under consideration in this article. The blood flow has been assumed to be non-linear, incompressible and fully developed. The artery is assumed to be an elastic cylindrical tube and the geometry of the stenosis considered as time dependent, and a co...
متن کاملA Numerical Analysis for the Effect of Slip Velocity and Stenosis Shape on Non-Newtonian Flow of Blood (TECHNICAL NOTE)
The aim of this paper is to study the effect of slip velocity and shape of stenosis on non-Newtonian flow of blood through a stenosed arterial segment. Blood is modeled as Bingham-Plastic fluid in a uniform circular tube with a radially non-symmetric stenosis. The problem is investigated by a joint effort of analytical and numerical techniques. The influence of stenosis shape parameter, slip ve...
متن کاملPrevalence of carotid arterial diseases in patients undergoing CABG operations
Introduction: Prevalence of stroke following coronary artery bypass graft surgery (CABG) is % 2.1-5.2 and associated with high mortality. The purpose of this study was to investigate the prevalence of carotid artery disease in patients undergoing CABG surgery. Methods: This cross-sectional study was performed in the years 2010-2011 on 192 patients who underwent open heart surgery (CABG) in...
متن کاملارتباط TFC) TIMI Frame Count) با کسر ذخیره جریانی (FFR) در بیماران مبتلا به تنگی متوسط عروق کرونر که تحت آنژیوگرافی کرونر قرار میگیرند
Background and Objective: Thrombolysis in myocardial infarction (TIMI) frame count (TFC) is an objective and quantitative index of coronary flow, and myocardial fractional flow reserve (FFR) is a lesion-specific index for epicardial coronary stenosis. Currently, FFR is the most valid tool for decision making in coronary interventions. However, it incurs relatively high costs and it is not reimb...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Cardiovascular research
دوره 47 2 شماره
صفحات -
تاریخ انتشار 2000