BACKGROUND & AIMS No generalizable formulas exist that are derived from bioelectrical impedance analysis (BIA) for predicting appendicular lean mass (ALM) and fat mass (AFM) in sarcopenic older adults. Since precision of regional body composition (BC) data in multicentre trials is essential, this study aimed to: 1) develop and cross-validate soft tissue BIA equations with GE Lunar and Hologic DXA systems as their reference 2) to compare our new ALM equation to two previously published models and 3) to assess the agreement between BIA- and DXA-derived soft tissue ratios as indicators of limb tissue quality. METHODS Two-hundred and ninety-one participants with functional limitations (SPPB-score 4-9; sarcopenia class I or II, measured by BIA) were recruited from 18 study centres in six European countries. BIA equations, using DXA-derived ALM and AFM as the dependent variable, and age, gender, weight, impedance index and reactance as independent variables, were developed using a stepwise multiple linear regression approach. RESULTS Cross-validation gave rise to 4 equations using the whole sample: ALMLUNAR (kg) = 1.821 + (0.168*height2/resistance) + (0.132*weight) + (0.017*reactance) - (1.931*sex) [R2 = 0.86 and SEE = 1.37 kg] AFMLUNAR (kg) = -6.553 - (0.093* height2/resistance) + (0.272*weight) + (4.295*sex) [R2 = 0.70 and SEE = 1.53 kg] ALMHOLOGIC (kg) = 4.957 + (0.196* height2/resistance) + (0.060*weight) - (2.554*sex) [R2 = 0.90 and SEE = 1.28 kg] AFMHOLOGIC (kg) = -4.716 - (0.142* height2/resistance) + (0.316*weight) + (4.453*sex) - (0.040*reactance) [R2 = 0.73 and SEE = 1.54 kg] Both previously published models significantly overestimated ALM in our sample with biases of -0.36 kg to -1.05 kg. For the ratio of ALM to AFM, a strong correlation (r = 0.82, P < 0.0001) was found between the mean estimate from BIA and the DXA models without significant difference (estimated bias of 0.02 and 95% LOA -0.62, 0.65). CONCLUSION We propose new BIA equations allowing the estimation of appendicular lean and fat mass. Our equations allow to accurately estimate the appendicular lean/fat ratio which might provide information regarding limb tissue quality, in clinical settings. Furthermore, these BIA equations can be applied to characterize sarcopenia with Hologic and Lunar reference values for BC. Previously published BIA-based models tend to overestimate ALM in sarcopenic older adults. Users of both GE Lunar and Hologic may now benefit from these equations in field research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Total Fat, Percentage of Fat, Trunk Fat, Soft Lean and Mass Waist-Hip Ratio between Diabetic type II and Matched Non-Diabetic Iranians using Bioelectrical Impedance Analysis

Introduction: Research shows a relationship between diabetes (type II) and obesity. Bioelectrical Impedance Analysis (BIA) is a relatively new and approved method for the measurement of body composition. The aim of this study was to compare diabetic and non-diabetic adults on the basis of waist-hip ratio, total fat, percentage of fat, trunk fat, and soft lean mass. Methods: In this cross-sec...

متن کامل

Bioelectrical Impedance versus Body Mass Index for Predicting Body Composition Parameters in Sedentary Job Women

Objective: Nowadays the value of bioelectrical impedance analysis (BIA) in the estimation of body adiposity both on a clinical basis in the individual and epidemiologically in large populations is of great interest. The current study determine accuracy of BIA compared with body mass index (BMI) measurement for estimating body composition in a group of normal weight employee women with a sedenta...

متن کامل

Comparisons of a Multi-Frequency Bioelectrical Impedance Analysis to the Dual-Energy X-Ray Absorptiometry Scan in Healthy Young Adults Depending on their Physical Activity Level

This study aimed at comparing BIA and DXA results in assessing body composition in young adults depending on their physical activity level. Eighty healthy 19-30 years old subjects were enrolled and their body composition (Fat Mass and Fat-Free Mass) was assessed by dual-energy X-ray absorptiometry (DXA) and by a newly developed Bioelectrical Impedance Analyzer (BIA - Tanita MC780). A seven-day ...

متن کامل

Comparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis

Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...

متن کامل

Bioelectrical impedance with different equations versus deuterium oxide dilution method for the inference of body composition in healthy older persons.

BACKGROUND There is no consensus regarding the accuracy of bioimpedance for the determination of body composition in older persons. OBJECTIVE This study aimed to compare the assessment of lean body mass of healthy older volunteers obtained by the deuterium dilution method (reference) with those obtained by two frequently used bioelectrical impedance formulas and one formula specifically devel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical nutrition

دوره 36 3  شماره 

صفحات  -

تاریخ انتشار 2017