Improvements for determining the modulation transfer function of charge-coupled devices by the speckle method.

نویسندگان

  • A M Pozo
  • A Ferrero
  • M Rubiño
  • J Campos
  • A Pons
چکیده

We present and evaluate two corrections applicable in determining the modulation transfer function (MTF) of a charge-coupled device (CCD) by the speckle method that minimize its uncertainty: one for the low frequency region and another for the high frequency region. The correction at the low-spatial-frequency region enables attenuation of the high power-spectral-density values that arise from the field and CCD response non-uniformities. In the high-spatial-frequency region the results show that the distance between the CCD and the aperture is critical and significantly influences the MTF; a variation of 1 mm in the distance can cause a root-mean-square error in the MTF higher than 10%. We propose a simple correction that minimizes the experimental error committed in positioning the CCD and that diminishes the error to 0.43%.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative analysis of techniques for measuring the modulation transfer functions of charge-coupled devices based on the generation of laser speckle.

Two methods for measuring the modulation transfer function (MTF) of a charge-coupled device (CCD) that are based on the generation of laser speckle are analyzed and compared. The method based on a single-slit aperture is a quick method, although the measurements are limited to values of less than the Nyquist frequency of the device. The double-slit method permits the measurement of values of as...

متن کامل

Design and Fabrication Process of MTF Phantom CT Scan

Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...

متن کامل

Defocusing Effect Studies in MTF of CCD Cameras Based on PSF Measuring Technique

Defocusing effects in modulation transfer function (MTF) measurement of charge coupled device (CCD) cameras is the main focus of current paper. We introduce measuring Point-spread function (PSF) in order to calculate the MTF and further more we will study the shape of MTF and its cut-off frequency by adjusting the lens focusing in different locations. A collimated white light LED by broadband s...

متن کامل

Investigation of a CCD modulation transfer function using the speckle method at different laser wavelengths and sub-windowing options

We have experimentally investigated the MTF of a scientific grade CCD, especially considering its behavior induced by different laser wavelengths (from 470 nm to 633 nm) and varying number of total charge transfers. The MTF measurements were performed using laser speckles and utilizing the single-slit method. The MTF of the sensor was examined from zero to the Nyquist frequency. The results obt...

متن کامل

Bistability in the Electric Current through a Quantum-Dot Capacitively Coupled to a Charge-Qubit

We investigate the electronic transport through a single-level quantum-dot which is capacitively coupled to a charge-qubit. By employing the method of nonequilibrium Green's functions, we calculate the electric current through quantum dot at finite bias voltages. The Green's functions and self-energies of the system are calculated perturbatively and self-consistently to the second order of inte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Optics express

دوره 14 13  شماره 

صفحات  -

تاریخ انتشار 2006