Quality control for SELDI analysis.

نویسندگان

  • C Nicole White
  • Zhen Zhang
  • Daniel W Chan
چکیده

Surface-enhanced laser desorption/ionization time of flight mass spectrometry (SELDI TOF-MS) studies have claimed significant success in identifying biomarkers with higher sensitivity and specificity for detecting disease than currently available diagnostic methods (1–3). While these studies demonstrated great promise, the quality of SELDI spectra was not evaluated systematically until two years ago. In 2003, the analysis of a published dataset demonstrated the role experimental bias can have in spectra quality (4). Several articles have since been published that investigate the reliability of SELDI spectra output. The article by Manual Aivado and colleagues (5) published in this issue of the journal should be a welcome addition to this important area of research. This article has demonstrated several important analytical parameters which may affect the experimental outcome of a SELDI study. First, the authors were able to show that automation improves spectra quality by reducing variation. Second, they provided additional evidence that peaks with a low signal to noise ratio (SNRF2) should be excluded from analysis. By increasing the SNRs from 2 to 5, the number of peaks was reduced as well as the peaks’ coefficients of variation (CV). Third, this article discussed a number of issues relating to SELDI reproducibility and demonstrated that standardization of analytical parameters was an important step toward better performance. In conducting SELDI experiments and performing data analysis, one should be aware of other important issues. First, using cluster analysis as a means of selecting an optimal number of replicates might be useful. However, many researchers are now spotting their samples in replicates. A comparison of different methods for identifying spectra replicate inconsistencies would also be informative. Second, while this study showed that freeze-thawing up to 5 cycles did not deteriorate the CVs significantly, the analysis methods used here may not be sensitive enough to detect a set of proteins which decay at a faster rate than the highly abundant proteins. Third, their evaluation of SELDI spectra quality seven months after the initial analysis is critical to evaluating spectra reproducibility. It would also be interesting to cluster all of the data from the two time points to determine if the sample identity or the time of analysis were more influential in defining the clusters. In the current literature, several articles have demonstrated that it is important to optimize SELDI experimental parameters in order to achieve good quality spectra. Therefore, one should define SELDI quality assurance and quality control (QA/QC). One of the first articles published used multi-factorial study design to identify optimal sample preparation and chip spotting procedures (6). However, unlike the article published here (5), a robot was not used, and their statistical analysis did not include cluster analysis. Another study was published just months later which used bioinformatics analysis to identify chips with questionable spectra quality (7). While this method was rather expensive in that one quarter of the chips’ spots were dedicated to assessing chip quality, it highlighted several issues which had heretofore been unexplored; including bias associated with chip and day of processing, and the need for a statistic to measure how different a spectrum is from other spectra observed on the same sample. And, finally, two multi-institutional SELDI studies will be published this year. In both studies, a set of standard protocols were used for sample processing, chip spotting, and spectra collection. The spectra obtained using these protocols were compared across multiple institutions. With these rigorous standard protocols, both studies obtained very consistent spectra. One of these was supported by the Early Detection Research Network and was published in January of this year (8). The second study was completed for the Human Proteome Organization and will be published this summer in Proteomics. The issues described here are not unique to SELDI analysis; they are shared by other large-scale proteomics expression analysis techniques. This research indicates that QC combined with standard operating procedures allows SELDI users to produce high quality spectra. The study by Manual Aivado and colleagues has provided additional evidence for improving reproducibility and standardization among SELDI experiments while highlighting factors that contribute to variability. Such research can only improve the quality of SELDI applications.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantitative quality-assessment techniques to compare fractionation and depletion methods in SELDI-TOF mass spectrometry experiments

MOTIVATION Mass spectrometry (MS), such as the surface-enhanced laser desorption and ionization time-of-flight (SELDI-TOF) MS, provides a potentially promising proteomic technology for biomarker discovery. An important matter for such a technology to be used routinely is its reproducibility. It is of significant interest to develop quantitative measures to evaluate the quality and reliability o...

متن کامل

SELDI-TOF analysis of glioblastoma cyst fluid is an approach for assessing cellular protein expression

OBJECTIVES In about 10% of glioblastoma patients, preoperative MRI discloses the presence of tumor cysts. Whereas the impact of cystic appearance on prognosis has been discussed extensively, only little is known about the tumor cyst fluid. In this study, we tested the feasibility of the surface enhanced laser desorption ionization time of flight (SELDI-TOF) technique to detect cyst fluid protei...

متن کامل

Serum Protein Expression Profiling for Cancer Detection: Validation of a SELDI-Based Approach for Prostate Cancer

Multiple studies have reported that analysis of serum and other bodily fluids using surface enhanced laser desorption/ionization time of flight mass spectroscopy (SELDI-TOF-MS) can identify a "fingerprint" or "signature" of spectral peaks that can separate patients with a specific disease from normal control patients. Ultimately, classification by SELDI-TOF-MS relies on spectral differences in ...

متن کامل

Serum biomarker screening for the diagnosis of early gastric cancer using SELDI-TOF-MS.

In this study, we performed a proteomic analysis of sera from stage I gastric cancer patients using surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) and established a diagnostic model for the early diagnosis of stage I gastric cancer. Serum samples from 169 gastric cancer patients and 83 age- and gender-matched healthy individuals were analyzed by SEL...

متن کامل

Plasma Protein Profiles Differ Between Women Diagnosed with Cervical Intraepithelial Neoplasia (CIN) 1 and 3

Early detection of precancerous cells in the cervix and their clinical management is the main purpose of cervical cancer prevention and treatment programs. Cytological findings or testing for high risk (HR)-human papillomavirus (HPV) are inadequately sensitive for use in triage of women at high risk for cervical cancer. The current study is an exploratory study to identify candidate surface-enh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 2005