Geometric parameters optimization of planar interdigitated electrodes for bioimpedance spectroscopy

نویسندگان

  • M. Ibrahim
  • J. Claudel
چکیده

This paper is concerned with a physical model of an interdigitated sensor working in a frequency range from 100 Hz to 10 MHz. A theoretical approach is proposed to optimize the use of the sensor for bioimpedance spectroscopy. The correlation between design parameters and frequency behavior in coplanar impedance sensors are described. CoventorWare software was used to model the biological medium loaded interdigital sensor in three dimensions to measure its electrical impedance. Complete system simulation by a finite element method (FEM) was used for sensor sensitivity optimization. The influence of geometrical parameters (number of fingers, width of the electrodes) on the impedance spectroscopy of the biological medium was studied. The simulation results are in agreement with the theoretical equations of optimization. Thus, it is possible to design a priori such sensor by taking into account the biological medium of interest that will load the sensor.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Planar Interdigital Sensor for Bio-impedance Measurement: Theoretical analysis, Optimization and Simulation

This paper proposes the design of a biosensor to characterize the dielectric and conductive properties of biological materials (for example blood or water) by impedance spectroscopy. Particularly, its design optimized the geometric structure interdigitated electrodes. This optimization allows extending the frequency range of measurement by reducing the polarization effect. Polarization effect i...

متن کامل

A new approach to microstructure optimization of solid oxide fuel cell electrodes

Designing optimal microstructures for solid oxide fuel cell (SOFC) electrodes is complicated due to the multitude of electro-chemo-physical phenomena taking place simultaneously that directly affect working conditions of a SOFC electrode and its performance. In this study, a new design paradigm is presented to obtain a balance between electrochemical sites in the form of triple phase boundary (...

متن کامل

Wideband Fully-Programmable Dual-Mode CMOS Analogue Front-End for Electrical Impedance Spectroscopy

This paper presents a multi-channel dual-mode CMOS analogue front-end (AFE) for electrochemical and bioimpedance analysis. Current-mode and voltage-mode readouts, integrated on the same chip, can provide an adaptable platform to correlate single-cell biosensor studies with large-scale tissue or organ analysis for real-time cancer detection, imaging and characterization. The chip, implemented in...

متن کامل

Bioimpedance spectroscopy tensor probe for anisotropic measurements

The tetrapolar electrode configuration used in bioimpedance suffers from negative sensitivity and is confounded by anisotropic tissue such as blood vessels or muscle and nerve fibres. We propose a circular array of electrodes to focus current directly underneath the probe and provide anisotropy information. We show that an implementation using 16 miniature electrodes is able to outperform the t...

متن کامل

Analysis of Planar Circular Interdigitated Electrodes for Electroporation

in this work, designs for planar, interdigitated circular electrode structures for cell membrane permeabilization procedures are analysed using finite element method analysis. The generated electric field intensity, homogeneity and the Joule heating are evaluated. The optimal electrode configuration for successful transfection procedures is investigated. Based on the simulation results, an opti...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013